Dimplex TS521W Series Скачать руководство пользователя страница 1

7207610100R02

LIMITED WARRANTY:

 

 All Dimplex Thermostats are warranted 

against defects in workmanship and materials for five years from 

date of sale.  This warranty does not apply to damage from accident, 

misuse, or alteration, nor where the connected voltage is more that 5 

% above the nameplate voltage, nor to equipment improperly installed 

or wired or maintained in violation of the instruction sheet.  This 

limited warranty applies only to purchases made in any province of 

Canada except for Yukon Territory, Nunavut, or Northwest Territories 

or in any of the 50 States of the USA (and the District of Columbia) 

except for Hawaii and Alaska.  This limited warranty applies to the 

original purchaser of the product only and is not transferable.  No 

other written or oral warranty applies.  No employee, agent, dealer 

or other person is authorized to give any warranties on behalf of 

Dimplex.  The customer shall be responsible for all costs incurred in 

the removal or reinstallation and shipping of the product for repairs.  

Within the limitations of this warranty, inoperative units shall be 

returned to the nearest Dimplex authorized service center, and we 

shall repair or replace, at our option, at no charge to you with return 

freight paid be Dimplex.  It is agreed that such repair or replacement 

is the exclusive remedy available from Dimplex and that DIMPLEX IS 

NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING 

INCIDENTAL AND CONSEQUENTIAL DAMAGE.  Some States do 

not allow the exclusion or limitation of consequential damages, so 

the above exclusion or limitation may not apply to you.  This warranty 

gives you specific legal rights and you may also have other rights 

which vary from state to state.

Line Voltage Electric Heater 

Thermostat 

TS521W/TD522W Series

 Installation Instructions

 Operation

 Warranty

FEATURES

Clean, attractive style suits any decore wall-mount design sits flush 

against wall.  Includes both 

o

C and 

o

F control dials

SPECIFICATIONS

Electrical Ratings:

0 - 2640 watts max. at 120 volts (22 amps)

0 - 4576/5280 watts at 208/240 volts (22 amps)

0 - 4986 watts at 277 volts (18 amps)

Sensing Element: 

Bimetal

Temperature Operating Range: 

5

o

 - 35

o

C and 41

o

 -

 

 95

o

F

Approvals:

Underwriters Laboratories Inc No.: E105830

Canadian Standards Association No.: LR30410

Figure 1

Cover

Outlet Box

Screw

Base

Index Plate

Recycling Notice

At the end of the electrical products useful life it should  

not be disposed of with household waste. Please recycle 

 

where facilities exist. Check with your Local Authority or 

 

retailer for recycling advice in your country.

Mounting: 

Mounts directly into a standard 2 x 4 inch vertical electri-

cal outlet box

SINGLE POLE THERMOSTAT INSTALLATION

 WARNING: 

The installation of the thermostat must comply with 

the applicable Local and/or National Electrical Codes and utility 

requirements.  This installation should be entrusted to duly qualified 

personnel where required by law.

 WARNING: 

Ensure that all wiring connections to the thermostat 

are correct and tight to prevent electrical shorts. Use the appropriate 

wire to meet local and national electrical codes for rated power 

consumption.

Disconnect power supply to prevent electrical shock or product 

1. 

damage.

Run line voltage wiring to the thermostat location.

2. 

Do not remove the thermostat cover.

3. 

Connect the red LINE lead on the thermostat to the L1 line 

4. 

from the power supply panel.

Connect the black LOAD lead from the thermostat to the line 

5. 

lead on the heater.

Connect the N Neutral (or L2) line to the remaining line of the 

6. 

heater.

Secure the ground wire to the ground screw provided in the 

7. 

outlet box.

Ensure that all connections are tight.

8. 

Insert wires into the outlet box taking care not to damage the 

9. 

sensing device or wiring.

Remove the thermostat cover by grasping the cover by the 

10. 

sides and pulling it away from the thermostat base.

Mount the thermostat base into the wall box and secure using 

11. 

the two supplied screws.

!

 NOTE:

 Do not over tighten mounting screws

Replace thermostat cover.

12. 

DOUBLE POLE THERMOSTAT INSTALLATION

 WARNING: 

The installation of the thermostat must comply with 

the applicable Local and/or National Electrical Codes and utility 

requirements.  This installation should be entrusted to duly qualified 

personnel where required by law.

 WARNING: 

Ensure that all wiring connections to the thermostat 

are correct and tight to prevent electrical shorts. Use the appropriate 

wire to meet local and national electrical codes for rated power 

consumption.

Disconnect power supply to prevent electrical shock or product 

1. 

damage.

Run line voltage wiring to the thermostat location.

2. 

Do not remove the thermostat cover.

3. 

Figure 2 - Single Pole Thermostat

L1 from 

Power Supply

Neutral from 

Power Supply

Line Red

Load Black

Wire 

Connector

Thermostat

Heater

Figure 3 - Double Pole Thermostat

L1 from 

Power Supply

Neutral from 

Power Supply

Line Red

Load Black

Wire 

Connector

Thermostat

Heater

Connect the black LOAD leads on the thermostat to the leads 

4. 

on the heater.

Connect the red LINE leads on the thermostat to the line leads 

5. 

from the power supply panel.

Ensure that all connections are tight.

6. 

Insert wires into the outlet box taking care not to damage the 

7. 

sensing device or wiring.

Secure the ground wire to the ground screw provided in the 

8. 

outlet box.

Remove the thermostat cover by grasping the cover by the 

9. 

sides and pulling it away from the thermostat base.

Mount the thermostat into the wall box and secure using the 

10. 

two supplied screws.

!

 NOTE: 

Do not over tighten mounting screws

Replace thermostat cover.

11. 

To adjust the temperature to your individual requirements, turn 

the thermostat control clockwise all the way to turn on the heater 

(Figure 4).  When the room reaches the desired temperature, turn 

the thermostat knob counter clockwise until you hear a click.  Leave 

in this position to maintain the room temperature at this setting.  For 

additional heat, turn clockwise until you hear the click again and the 

heater will turn on.

For single pole models:-

 Turning the knob fully counter clockwise 

will set the temperature rating to 5

o

C (41

o

F). 

For double pole models:-

Turning the knob fully counter clockwise 

will disconnect the power to the heater.

INDEX PLATE REMOVAL 

(Figure 5)

Using a small flat screwdriver or other suitable tool gently pry up on 

one of the slots located on the index plate.  To install line up the index 

plate pins with the holes in the thermostat knob and push until the 

index plate is flush with the thermostat knob.

Figure 4

Figure 5

In keeping with our policy of continuous product improvement, 

we reserve the right to make changes without notice. 

© 2011 Dimplex North America Limited

1367 Industrial Road     Cambridge ON Canada N1R 7G8

1-888-346-7539  

  www.dimplex.com

Отзывы: