www.dimplex.de 452231.66.11 · FD 9208
EN-11
English
SIK 11ME - SIK 16ME
12 Device Information
1
Type and order code
SIK 11ME
SIK 16ME
2
Design
2.1
Model
Compact
Compact
2.2
Degree of protection according to EN 60 529
IP 20
IP 20
2.3
Installation Location
Indoors
Indoors
3
Performance data
3.1
Operating temperature limits:
Heating water flow
°C
Up to 55
Up to 55
Brine (heat source)
°C
-5 to +25
-5 to +25
Antifreeze
Monoethylene glycol
Monoethylene glycol
Minimum brine concentration (-13 °C freezing temperature)
25%
25%
3.2
Temperature spread of heating water (flow/return flow)
at B0 / W35
K
9.9
10
3.3
Heat output / COP
at B-5 / W55
1
kW / ---
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
9.4 / 2.4
13.3 / 2.2
at B0 / W50
1
kW / ---
11.3 / 3.0
15.5 / 2.9
at B0 / W35
1
kW / ---
11.8 / 4.4
15.8 / 4.2
3.4
Sound power level
dB(A)
51
51
3.5
Heating water flow with an internal pressure differential of m³/h / Pa
1.0 / 3500
1,3 / 3500
3.6
Free compression of heat circulating pump (max. level)
Pa
65500
43500
3.7
Brine throughput with an internal pressure differential
(heat source) of
m³/h / Pa
3.0 / 13000
3.5 / 13000
3.8
Free compression of brine circulating pump (max. level) Pa
40000
34000
3.9
Refrigerant; total filling weight
type / kg
R407C / 2.0
R407C / 2.3
3.10 Lubricant; total filling weight
type / litres
Polyolester (POE) / 1.36
Polyolester (POE) / 1.90
4
Dimensions, connections and weight
4.1
Device dimensions without connections
2
H x W x L mm
2. Note that additional space is required for pipe connections, operation and maintenance.
1115
652
688
1115
652
688
4.2
Device connections to heating system
Inch
R 1¼" external
R 1¼" external
4.3
Device connections to heat source
Inch
R 1¼" external
R 1¼" external
4.4
Weight of the transportable unit(s) incl. packing
kg
191
203
5
Electrical connection
5.1
Nominal voltage; fuse protection
V / A
230 / 25
230 / 32
5.2
Nominal power consumption
1
B0 W35
kW
2.66
3.77
5.3
Starting current with soft starter
A
38
45
5.4
Nominal current B0 W35 / cos
A / ---
14.46 / 0.8
20.5 / 0.8
6
Complies with the European safety regulations
3
3. See CE declaration of conformity
3
7
Additional model features
7.1
Water in device protected against freezing
4
4. The heat circulating pump and the heat pump manager must always be ready for operation.
Yes
Yes
7.2
Performance levels
1
1
7.3
Controller internal/external
Internal
Internal
Содержание SIK 11 ME
Страница 2: ......
Страница 26: ...EN 12 452231 66 11 FD 9208 www dimplex de English SIK 11ME SIK 16ME ...
Страница 38: ...FR 12 452231 66 11 FD 9208 www dimplex de Français SIK 11ME SIK 16ME ...
Страница 45: ...www dimplex de 452231 66 11 FD 9208 A VII Anhang Appendix Annexes SIK 11ME SIK 16ME 3 2 Last Load Charge ...