background image

7213140100R02

Architectural Heaters 

SAF6/SAS8 Series

 Installation Instructions

 

IMPORTANT INSTRUCTIONS

When using electrical appliances, basic precautions should al-

ways be followed to reduce the risk of fire, electric shock, and 

injury to persons, including the following:
1.  Read all instructions before using the heater.
2.  The heater is hot when in use. To avoid burns, do not let 

bare skin touch hot surfaces. The trim around the heater 

outlet becomes hot during heater operation. Keep com-

bustible materials, such as furniture, pillows, bedding, pa-

pers, clothes, and curtains at least 3 ft (0.9 m) from the 

front of the unit and keep them away from the sides and 

rear.

3.  Extreme caution is necessary when any heater is used by 

or near children or invalids and whenever the unit is left 

operating and unattended.

4.  Do not operate any heater after it malfunctions. Discon-

nect power at the service panel and have the heater in-

spected by a reputable electrician before reusing.

5.  Do not use outdoors.
6.  To disconnect the unit, turn the controls off, and then 

switch off at main power supply panel.

7.  Do not locate these heaters below any electrical conven-

ience receptacles.

8.  Do not install these heaters against combustible, low 

density cellulose fibre surfaces.

9.  Do not insert or allow foreign objects to enter any venti-

lation or exhaust opening as this may cause an electric 

shock or fire, or damage to the heater.

10. 

To prevent a possible fire, do not block air intake or ex

-

haust in any manner.

11.  All electrical heaters have hot and arcing or sparking parts 

inside. Do not use in areas where gasoline, paint, or flam

-

mable liquids are used or stored.

12. Do not modify this heater. Use it only as described in this 

manual. Any other use not recommended by the manufac-

turer may cause fire, electric shock or injury to persons.

SAVE THESE INSTRUCTIONS

   WARNING: 

Wiring procedures and connections should 

be in accordance with the National Electric Code (NEC & 

CEC) and local codes.

 WARNING: 

To reduce the risk of fire, do not store or use 

gasoline or other flammable vapors or liquids in the vicinity of 

the heater.

 CAUTION:

  High  temperature,  risk  of  fire,  keep  electrical 

cords, drapery, furnishings, and other combustibles at least 

3 feet (0.9 m) from the front of the heater.

Recommendations for Locating Drapes and Furniture 

near Heaters

For most satisfactory operation of the baseboard heaters and 

minimum effect on drapes and furniture, the following recom-

mendations should be observed:
1.  Hang drapes so that, in use, they extend below the center 

line of the heater, but with at least 1.5 inches clearance from 

the finished floor covering (such as carpet, if used).

2.  Hang drapes so that there is at least 3 inches between the 

extreme front of the heater and the nearest fold of the drapes 

in the folded back (opened drape) position.

3.  Hang drapes so there is at least 1.5 inches between the top 

of the drapes and the ceiling.

4.  To be suitable for draperies located close to heaters, mate-

rial should not discolour nor distort dimensionally (stretch or 

shrink) upon extended exposure (1000 hrs.) to a temperature 

of 200º F (93º C).

!

 NOTE: 

If drapes are to be cut off above a heater, they 

should be cut off at least 6 inches above the top of the heater 

and preferably more.

!

 NOTE: 

Place furniture no closer then 3 inches from the  

baseboard heater.

Wall Installation

1.  Unpack the heater from the carton and lift the front/top 

panel up & off the heater.

2.  Remove the desired terminal box covers(s) and supply 

wire entry knockouts from the terminal boxes.  (See Figure 

1 for locations)

!

 NOTE:

 It is only necessary to remove the knockout(s) that 

will feed the power supply wiring, keeping in mind the heater 

mounting location and supply wire location in the wall.
3.  Determine the correct mounting height and scribe or snap 

a level line on the wall to maintain each heater back plate 

in a horizontal alignment, when mounting.

!

 NOTE: 

Bottom air inlet heaters must be mounted a 

minimum of 2” from the bottom of the heater to the finished 

floor.

4.  Mount the back plate to the wall using suitable fasteners 

(provided by the customer) using the scribed line on the 

wall to keep the heater level.

!

 NOTE: 

Should the wall surface be uneven, secure the 

1.5 in 

(3.81 cm)

min

1.5 in (3.81 cm)

min

1.5 in (3.81 cm)

min

3 in (7.62 cm)

min

3 in (7.62 cm)

min

3 in (7.62 cm)

min

6 in (15.24 cm)

min

Отзывы: