background image

INDPGEELRG Issue 0

Montage- und Gebrauchsanweisung

Instructions for Installation and Use
Instructions de montage et de service

EPX 500 ... EPX 2500

 

Wandkonvektor

Convector Heater
Convecteur de Base Mural

RX TI 24

24 Stunden Programmierkassette

24-Hour Programming Cassette
Cassette de programmation 24 heures

RX PW 1

7 Tage Programmierkassette

7-Day Programming Cassette
Cassette de programmation 7 jours

RX TI RB

 

Ablauf Timer

Runback Timer
Programmateur minuterie

Содержание RX TI RB

Страница 1: ... 500 EPX 2500 Wandkonvektor Convector Heater Convecteur de Base Mural RX TI 24 24 Stunden Programmierkassette 24 Hour Programming Cassette Cassette de programmation 24 heures RX PW 1 7 Tage Programmierkassette 7 Day Programming Cassette Cassette de programmation 7 jours RX TI RB Ablauf Timer Runback Timer Programmateur minuterie ...

Страница 2: ...d by the person using the bath or the shower Do not install the heater immediately below a power socket The electrical connection box must be accessible after the heater has been mounted Be careful of flammable objects It is absolutely necessary that the minimum clearances indicated in the mounting diagram be maintained Beyond that a clearance space of at least 500 mm is to be allowed in front of ...

Страница 3: ...ase check that the heater is switched on and that the thermostat is set to the desired temperature Subsequently check the circuit breaker on the main service panel or the fuse to ensure that they have not tripped or blown When a programming cassette is used check that the program ON is active also refer to the operating instructions of the programming cassettes on the pages that follow If the faul...

Страница 4: ...ed off 5 Automatic Mode Switch on the heater Press the PROG button twice P1 ON appears on the display and the hours flash Set the hours using the buttons confirm with ENTER Use the same procedure to set the minutes Confirm with ENTER Note Minutes can be set in 10 minute increments only P1 OFF now appears on the display Set the desired switch off time and confirm with ENTER Program P1 has thus been...

Страница 5: ... are set Press the PROG button twice P1 ON appears on the display and the hours flash Set the hours using the buttons confirm with ENTER Use the same procedure to set the minutes Confirm with ENTER Note Minutes can be set in 10 minute increments only P1 OFF now appears on the display Set the desired switch off time and confirm with ENTER Program P1 has thus been set P2 now appears i e another heat...

Страница 6: ...osition Select a heater operating time and set the miniature switches accordingly 2 Installation Switch off heater Using a narrow bladed screwdriver release the cover Insert the programming cassette fully into the opening If necessary the cassette can be secured against unauthorised removal by means of the screw supplied 4 Start Up Switch on heater and set thermostat to the desired temperature Pre...