background image

 

Electronic Radiant Panel Heater

                                                                                      

Models

:

  

RPX075N / RPX100N / RPX150N / RPX200N 

Dimensions and Specification 

Model Loading 

Length 

(A) 

Height Depth  X 

Weight 

  

(kW) (mm) 

(mm) 

(mm) 

(mm) 

(mm) 

(mm) 

(kg) 

RPX075N 0.75 

515  440 110 178 

124.5 

212.5 4.3 

RPX100N 1.0 

620  440 110 

248 

159.5 

212.5 

5.3 

RPX150N 1.5 

830  440 110 

405 

212.5 

212.5 

7.2 

RPX200N 2.0  1040  440 110 

535 

252.5 

252.5 

9.0 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

               

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

  

 
                                                                                                                                                              
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

Installation and Operating Instructions    

Wall Mounting / Installation 

The heater should be positioned observing the minimum clearances 
stated around the heater. 
(see also ‘Electrical’ section) 

 

The wall bracket supplied with the heater must be used 

 

1. 

Remove wall mounting bracket from back of heater by de pressing 
the two spring latches at the top of the heater (see Fig.1) 

2. 

Fix wall bracket securely to wall via the three or four holes in the 
bracket with the appropriate fixings for the wall type (see Fig.2) 

3. 

Present heater to wall bracket and engage the two lower slots first. 
Then line up and push in the top two slots until the spring latches 
click in to place 

General 

The compact RPX range of radiant panel heaters are designed to 
provide comfortable radiant heat in both domestic and commercial 
applications.

 

Model A 

(Width) 

(Bracket 

Width) 

RPX075N 515 

178 

212.5 

RPX100N 620 

248 

212.5 

RPX150N 830 

405 

212.5 

RPX200N 1040 

535 

252.5 

IMPORTANT SAFETY ADVICE 

 

 

When using electrical appliances, basic precautions should always be 
followed to reduce the risk of fire, electrical shock, and injury to 
persons, including the following: 

 

WARNING THE SURFACES OF THIS HEATER CAN BE HOT 
Momentary contact with any part of the heater should not cause injury. 
However, aged or infirm persons or young children should not be left 
unsupervised in the vicinity of the heater unless a suitable guard is 
fitted 

 

IMPORTANT – If this heater is installed in a room containing a bath or 
shower, it should be so installed that switches and other controls 
cannot be touched by a person using a bath or shower – to comply 
with this requirement see ‘Lock the Control Cover’ section on page 2. 

 

If you use this heater in conjunction with an external thermal control, a 
programme controller, a timer or any other device which switches the 
heat on automatically, observe all safety warnings AT ALL TIMES since 
a fire risk exists when the heater is accidentally covered or displaced 

 

The installation of this product should be carried out by an electrician 
or competent person and be in strict accordance with the current IEE 
Wiring Regulations and relevant Building Regulations 

 

This heater must not be mounted within 150mm of curtains and other 
combustible materials or 100mm from a shelf or overhang 

 

NEVER cover or obstruct in any way the heat outlet slots at the top of 
the heater or the air inlet slots at the base of the heater 

 

DO NOT cover the heater – Do not place material or garments on the 
heater or obstruct the air circulation around the heater  

 

Before connecting the heater check that the supply voltage is the same 
as that stated on the heater 

 

The heater must be installed in accordance with these instructions 

 

The heater must be mounted using the wall bracket supplied. The 
heater should only be operated in the upright position 

 

The heater should be positioned in accordance to the clearances 
stated in these instructions 

 

DO NOT locate this heater immediately beneath a fixed socket outlet

 

Pilot Wire Connection 

The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex 
programmers. If, however a programmer is not being used, the pilot wire should be 
isolated in accordance with the current IEE Wiring Regulations. 
Do 

NOT

 connect the BLACK pilot wire to earth 

Any 240V insulated cable may be used to link pilot wires around the ring main. A low 
signal current is used. Suitable connections would be either an additional single core wire 
marked or colour coded appropriately or use a 4 core cable throughout the ring main. 
Please refer to the relevant programmer installation and operating instructions for further 
details on pilot wire connection

 

Electrical 

The wires in the mains lead are coloured in accordance with the following code: 

GREEN & YELLOW    EARTH 
BLUE NEUTRAL 
BROWN LIVE 
BLACK PILOT 

WIRE 

(See also ‘Pilot Wire Connection’) 

The heater is fitted with a length of flexible cable for connection to the fixed wiring of 
the premises through a suitable connection box positioned adjacent to the heater. 
The supply circuit to each heater must incorporate a double pole isolating switch having 
a contact separation of at least 3mm 

 

Fig.1 

Fig.2 

IP24       

Issue 3   October 2010

 