IMPORTANT INSTRUCTIONS

When using electrical appliances, basic precautions should al-

injury to persons, including the following:

1.  Read all instructions before using the heater.

2.  The heater is hot when in use. To avoid burns, do not let 

bare skin touch hot surfaces. The trim around the heater 
outlet  becomes  hot  during  heater  operation.  Keep  com-
bustible materials, such as furniture, pillows, bedding, pa-
pers, clothes,  and  curtains  at  least  3  ft  (0.9  m)  from  the 
front of the unit and keep them away from the sides and 
rear.

3.  Extreme caution is necessary when any heater is used by 

or near children or  invalids and whenever the unit  is left 
operating and unattended.

4.  Do  not  operate  any  heater  after  it  malfunctions.  Discon-

nect power at the service panel and have the heater ins-
pected by a reputable electrician before reusing.

5.  Do not use outdoors.

6.  To  disconnect  the  unit,  turn  the  controls  off,  and  then 

switch off at main power supply panel.

7.  Do  not insert or  allow  foreign  objects to enter any venti-

lation  or  exhaust  opening  as  this  may  cause  an  electric 

8. 

-

haust in any manner.

9.  All electrical heaters have hot and arcing or sparking parts 

-

mable liquids are used or stored.

10.  Do not modify this heater. Use it only as described in this 

manual. Any other use not recommended by the manufac-

SAVE THESE INSTRUCTIONS

 WARNING: 

the heater.

 CAUTION:

cords, drapery, furnishings, and other combustibles at least 3 
feet (0.9 m) from the front of the heater.

This heater is designed for permanent installation only. Care 
should  be  taken  to  install  according  to  the  following  instruc-
tions. All required clearances should be  maintained. In addi-
tion  all  electrical  wiring  and  connections  should  comply  with 
local electrical codes.

!

 NOTE: 

It  is extremely important to read all information  la-

bels. Care must be taken to ensure that the heater is rated the 
same  voltage  as  the  electrical  supply  wires.  Failure  to  do  so 
could result in unsafe heater operation as well as damage to the 
unit. If replacing an existing heater, check the labels of the old 
heater to ensure the voltage of the new heater is compatible.

Multi-Directional Grille Orientation

Figure 1

Recess Box

Wiring Access

Figure 2

Alternate Multi-Directional Grille Orientation

!

 NOTE: 

Maintain a minimum clearance of 8” from adjacent 

All  units should be controlled by means  of  a regulating ther-
mostat.  Certain  models  only  are  provided  with  built  in  ther-
mostats. Check the 

Model Key Information 

section for veri-

wattage of all heaters on the circuit.

All installations require the following components:

1) Recess Box (Model 1011650100)
2) Heater Assembly (See nameplate Label)
3) Grille

An  optional  Surface  Mount  Box  is  available  for  installations 
that are not recessed in wall cavity.

Step 1 – Placement

All  units  are  designed  for  placement  in  either  interior  or  ex-
terior  walls.  Care  should  be  taken  to  provide  a  minimum  of 

in any way. Maintain 3’ (91.4cm) clearance of objects from the 
front of unit. Maintain a spacing of 3’ (91.4cm) between heat-
ers in  order to prevent re-circulation of heated air. Insulation 
surrounding the back and sides of the recess mount box will 
not affect performance. Ensure insulation is rated for tempera-
tures up to 185°F (85°C).

!

  NOTE: 

-

ticularly those incorporating clear vinyl materials tend to distort 
at temperatures in the vicinity of 140°F (60°C). Material shall 
be  checked  prior  to  installation  to  determine  if  discoloration 

ceilings. Do not install in any area where combustible vapors, 