background image

7211820100R00

Ceiling Heater

FFCH5000W Series

  Warning:  

Wiring procedures and connections should 

be in accordance with the National Electric code (NEC & 

CEC) and local codes.

  CaUTiOn: 

This heater is intended for permanent ceiling 

mounting only.

!

  nOTE: 

The heater has thermal cut-off protection. If the 

thermal cut-off protection trips, de-energize the unit. 

The unit should reset automatically after 10 minutes. If 

the thermal cut-off protection trips again, determine the 

reason for overheating.

!

  nOTE:  

A thermostat control (customer supplied) is re-

quired to operate this unit.

 installation instructions

 

impOrTanT inSTrUCTiOnS

When using electrical appliances, basic precautions should 

always be followed to reduce the risk of fire, electric shock 

and injury to person, including the following: 

Read all instructions before using this heater.

1. 

This heater is hot when in use. To avoid burns, do not let 

2. 

bare skin touch hot surfaces. If provided, use handles 

when moving this heater. Keep combustible materials 

such as furniture, pillows, bedding, papers, clothing and 

curtains at least 3 feet (0.9 m) away from front, sides and 

rear of the heater.
Extreme caution is necessary when any heater is used 

3. 

by or near children or individuals with disabilities and 

whenever the heater is left operating and unattended.
Always turn off heater when not in use.

4. 

Do not operate any heater with a damaged cord or plug 

5. 

or after the heater malfunctions, has been dropped or 

damaged in any manner.
Do not use outdoors.

6. 

Do not install less than 2.4 m (8 feet) from the floor and 

7. 

closer than 30.5 cm (12 inches) from any vertical surface 

or walls.
This heater is not intended for use in bathrooms, laundry 

8. 

or similar locations. Never locate heater where it may fall 

into a bathtub or water.
Do not insert or allow foreign objects to enter any ventila-

9. 

tion or exhaust openings. Do not block any ventilation or 

exhaust openings.
A heater may emit arcing or sparking inside the unit. 

10. 

Do not use in areas where gasoline, paint or flammable 

liquids are used or stored.
Use this heater only as described in this manual. Any 

11. 

other use not recommended by the manufacturer may 

cause fire, electric shock or injury to persons.

This heater is not intended for use with an extension 

12. 

cord.

SavE THESE inSTrUCTiOnS

Loosen the 4 screws to remove the grille box of the unit.

1. 

Loosen 1 screw to remove the mounting bracket.

2. 

Keep the unit at least 2.4m (8 ft.) away from the floor. 

3. 

This minimum distance must be maintained. (Figure 1)
Once the mounting position is decided, mark the drill-

4. 

hole positions in the ceiling for the mounting bracket.
Drill the required holes with the correct diameter bit 

5. 

for the anchors provided for positioning the mounting 

bracket.
Insert the anchors.

6. 

Attach the mounting bracket to the ceiling and secure 

7. 

with mounting screws.
Loosen 2 screws to remove the wiring compartment 

8. 

cover.
Hook the unit to the mounting bracket and let the unit 

9. 

hang from the mounting bracket. (Figure 3)
Run the electrical supply cable to the wiring compartment 

10. 

of the unit. Connect the grounded wire to the grounding 

screw and connect the electrical wires with provided wire 

connectors. (Figure 2)

Figure 1