background image

1

GB

EF 6/20
EF 6/20 TI
EF 6/20 TID
EF 6/10

1. Warnings

1.1. General

You are requested to read carefully all the information in these
instructions. It gives important information concerning the safety,
installation and mounting, use and servicing of the appliance. Keep
these instructions carefully and if applicable pass them on the final
owner.

The manufacturer is not responsible if the following directions are
not followed.

Dispose of the packaging properly.

If the appliance is damaged, check immediately with the
supplier before installation.

In order to guarantee the safe operation of the heater, it must
only be mounted and connected according to the directions in
the operating instructions.

The appliance is only to be used for its stated uses.

In the event of a fault disconnect the electricity supply to the
appliance (pull out the plug, alternatively turn off or remove
the fuse).

When the appliance is out of operation for a long period,
disconnect the electricity supply to the appliance.

Repairs to electrical appliances must only be performed by a
competent electrician.

1.2. Specific to this appliance

It is only suitable for domestic use or similar purposes within
enclosed space.

It is particularly important that the appropriate safety
regulations for bathrooms, showers etc. are fulfilled. The
heater is to be installed in such a way that it cannot be
touched from a bath or shower and that the switch cannot be
operated. The installation and electricity supply can only take
place in safety zone 3 according to VDE 0100 Part 701.

The heater is very hot inside. By covering the heater or by
placing or moving it within the specified minimum clearances
could cause a heat build up and possible lead to material
igniting. You must observe the minimum clearances.

No materials can be used in the room where the appliance is
installed whose fumes or the material could give rise to
ignition, explosion or thermal decomposition due to the high
temperatures. In such case (e.g. sticking down of floor
coverings) first ensure that the appliance have cooled down
to room temperature.

The surfaces, especially the grille, become hot during
operation. For this reason ensure that small children or infirm
people cannot touch these surfaces.

No objects should be inserted through the openings of the
appliance. This could lead to functional faults, possibly to the
ignition of the object.

Warning!

 There may be dangers following the automatic

switching on of connected heaters in your absence, e.g.
heaters which have been moved or covered in the meantime
could cause a fire.

Supply cord must not be placed over the hot heater.

2. Description

These instructions are valid for:
Rapid Heater EF 6/10, Heating capacity 1000W;
Rapid Heater EF 6/20, Heating capacity 2000W;
Rapid Heater EF 6/20 TID, Heating capacity 2000W with 24 h
clock;
Rapid Heater EF 6/20 TI, Heating capacity 2000 – 1000 W with
60 min timer.

Supply voltage: 1/N/PE ~ 230V 50Hz.
Dimensions: (B x H x T) 300 x 400 x 100 mm

Mounting: vertical on a wall

The fan heater is supplied with a thermostat, supply cord and plug.

The heater is splashproof IPX3, construction class I.

3. Minimum clearances, mounting

The rapid heater must only be installed in the vertical position. The
heater must not be located immediately below a fixed socket
outlet.

The minimum clearances given in the diagram must be observed.

Dimensions in mm

Furthermore a clearance of at least 750mm is to be maintained
from the front of the heater. With easily combustible objects such
as curtains or heat sensitive plastic, ensure that these are not
blown upon the hot air stream.

The rapid heater must only be mounted on a vertical non-
inflammable wall.

The heater must be secured to the wall with 3 screws (see
diagram). Use the screws and wall plugs in the enclosed plastic
bag.

Installation

Fix the heater as shown in the diagram.

Отзывы: