Heater Location
Minimum Clearances
WARNING:
The heating surface of the DLW must be positioned at a minimum of 96" (2.4 m) from the ground.
Objects below the heater, such as tables, must be no less than 39" (1000 mm) away from the heater.
Figure 5
shows the minimum clearances around the heater. All dimensions shown are minimum values.
Angled
Wall
Installation
Ceiling
Installation
Angled
Ceiling
Installation
Heater clearance to objects
should be minimum 39
"
Heater clearance to objects
should be minimum 39
"
Heater clearance to objects
should be minimum 39
"
59"
1500 mm
59"
1500 mm
12"
300 mm
12"
300 mm
4"
100 mm
4"
100 mm
4"
100 mm
4"
100 mm
39"
1000 mm
39"
1000 mm
39"
1000 mm
39"
1000 mm
96"
2400 mm
96"
2400 mm
96"
2400 mm
Lights, fans, and sprinklers
must NOT be below heater
Lights, fans, and sprinklers
must NOT be below heater
Lights, fans, and sprinklers
must NOT be below heater
Figure 5