background image

9

Heater Location

Minimum Clearances

    

WARNING: 

The heating surface of the DLW must be positioned at a minimum of 96" (2.4 m) from the ground. 

Objects below the heater, such as tables, must be no less than 39" (1000 mm) away from the heater.

Figure 5

 shows the minimum clearances around the heater. All dimensions shown are minimum values.

Angled   

Wall  

Installation  

Ceiling  

Installation

 

Angled  

Ceiling  

Installation

 

 

 

 

 

 

 

 

 

Heater clearance to objects

should be minimum 39

"

Heater clearance to objects

should be minimum 39

"

Heater clearance to objects

should be minimum 39

"

 

 

 

 

 

 

 

59"

1500 mm

59"

1500 mm

12"

300 mm

12"

300 mm

4"

100 mm

4"

100 mm

4"

100 mm

4"

100 mm

39"

1000 mm

39"

1000 mm

39"

1000 mm

39"

1000 mm

96"

2400 mm

96"

2400 mm

96"

2400 mm

Lights, fans, and sprinklers

must NOT be below heater 

Lights, fans, and sprinklers

must NOT be below heater 

Lights, fans, and sprinklers

must NOT be below heater 

Figure 5

Содержание DLW1500B12

Страница 1: ...nstructions contained in this manual to prevent personal injury or property damage To view the full line of Dimplex products visit www dimplex com 7216440100R02 Share the warmth and leave a review dim...

Страница 2: ...sion Mounting 14 Electrical Installation 15 Operation 17 Maintenance 17 Troubleshooting 18 Warranty 19 Conventions used in this manual NOTE Procedures and techniques that are considered important enou...

Страница 3: ...ank you and congratulations for choosing to purchase a Dimplex radiant heater Please carefully read and save these instructions WARNING Read all instructions and warnings carefully before starting ins...

Страница 4: ...sary when any heater is used by or near children or people with disabilities and whenever the heater is left operating and unattended Do not operate any heater after it malfunctions Disconnect power a...

Страница 5: ...ed for any other purpose Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons Before commencing installation make sure the electrical supply voltage is...

Страница 6: ...provals CSA UL E321448 Mounting Height Minimum 96 2 4 m Recommended Maximum 105 2 7 m Mounting Options Provided bracket suitable for ceiling and wall installation Extension poles for mounting on highe...

Страница 7: ...t the heater be positioned directly above the area to be heated with an ideal mounting height of 96 to 105 2 4 m to 2 7 m Heater Location Model Indoor Protected ft2 Outdoor Enclosed ft2 Outdoor Expose...

Страница 8: ...aters required to heat common residential table settings These configurations are based on DLW heaters being mounted at 96 2 4 m from the floor in a fully enclosed outdoor area Heater Location DLW1500...

Страница 9: ...all Installation Ceiling Installation Angled Ceiling Installation Heater clearance to objects should be minimum 39 Heater clearance to objects should be minimum 39 Heater clearance to objects should b...

Страница 10: ...ng or installation with the optional extension poles sold separately is recommended to reduce the height of the heater to 96 to 105 2 4 m to 2 7 m This will increase the effectiveness of your DLW heat...

Страница 11: ...s to be mounted on an incline such as on a vaulted ceiling ensure the electrical connection is located at the lowest point of the heater Figure 7 For wall mounted installations ensure heater is angled...

Страница 12: ...el 22 5 or 45 The brackets need to be mounted onto a secure frame or wall with a minimum distance between the two brackets Figure 9 Installation Model Minimum distance between brackets X DLW1500 21 55...

Страница 13: ...ting brackets need to be mounted onto a secure frame or wall with a minimum distance between the two brackets Figure 9 p 12 When completing the installation ensure all screws are tight and unit is sec...

Страница 14: ...re the wire chain has a suitable load rating for the heater The wire or chain is connected to the lower part of the standard brackets Figure 13 The brackets need to be mounted onto a secure frame or w...

Страница 15: ...ommercial heating applications within indoor or outdoor area and should not be used for any other purpose Any other use not recommended by the manufacturer may cause fire electric shock or injury to p...

Страница 16: ...plied with unit is installed to maintain rain water ingress protection rating of the heater Failure to install correctly will void the manufacturer s warranty Wall Switch Wall Switch Heater Junction B...

Страница 17: ...r with a mild detergent to remove the built up contaminants from the environment Thoroughly rinse all detergent off the heater After cleaning turn the heater on for 20 minutes to dry any water residue...

Страница 18: ...re are multiple heaters on one circuit ensure they are wired in parallel not in series Discoloration of the heater housing Heater is overheating Ensure the unit is wired with the correct voltage Envir...

Страница 19: ...quires a proof of purchase of the product What Glen Dimplex Americas will do in the event of a defect In the event a product or part covered by this limited warranty is proven to be defective in mater...

Страница 20: ...ct improvement we reserve the right to make changes without notice 2021 Glen Dimplex Americas Share the warmth and leave a review dimplex com sharethewarmth Your input helps to create even better prod...

Отзывы: