TROUBLESHOOTING GUIDE - DLG1058

PROBLEm

CaUSE

SOLUTION

General

Circuit breaker trips or fuse 

blows when unit is turned on

Short in unit wiring.

Trace wiring in unit.

Improper circuit current rating

Additional appliances may exceed the current 

rating of the circuit breaker or fuse.  Plug unit into 

another outlet or install unit on a dedicated 15 

amp circuit.

Unit turns on or off by itself

Remote control has a similar frequen-

cy to other remotes in the area.

Replace Remote Control.  Initialize to Remote 

Control Receiver.

Radio frequency disturbance from 

outside sources.

Change the CODE on the Remote Control (see 

operation section). Initialize Remote Control and 

Receiver

Defective Remote Control Receiver

Replace Remote Control Receiver.  Initialize to 

Remote Control.

Lights dim in room while the 

unit is on

Unit is drawing close to circuit current 

rating

Move the unit to another outlet or install unit on a 

dedicated 15 amp circuit

Power cord gets warm

Normal Operation

The power cord may get slightly warm to the 

touch when the heater is on

Defective power cord

Replace power cord if cord gets hot to the touch.

appearance

Log grate does not turn on in 

Manual Mode

Improper operation

Refer to Operation Section

No incoming power from the electrical 

wall socket

Check Fuse/Breaker Panel

Defective On/Off Switch

Replace On/Off Switch

Defective Remote Control Receiver

Replace Remote Control Receiver. Initialize with 

Remote Control.

Log grate does not turn on in 

Remote Mode

Improper operation

Refer to Operation Section

Remote control not initialized to log 

grate

Initialize the remote control

Loose wiring

Check wiring connections

Remote Control not working

Install new battery into the Remote Control.  Re-

initialize remote control where necessary
Replace Remote Control Receiver where nec-

essary.  Initialize Remote Control Receiver to 

Remote Control.

Defective Remote Control Receiver

Replace Remote Control Receiver.  Initialize to 

Remote Control

Flame Frozen

Loose wiring

Check wiring connections

Defective flicker motor

Replace flicker motor

Flame not bright or flame not 

visible

Loose wiring

Check wiring connections

Defective LED lights

Replace Log Grate Assembly

All logs dim, not glowing

Loose connection

Check wiring connections

Defective Log Grate wiring

Replace Log Grate Assembly

One Log dim, not glowing

Loose connection

Check wiring connections

Defective LED in Log

Connect log to another log grate connection to 

verify if log works.  

If log works, wiring defective - Replace Log 

• 

Grate Assembly

If log does not work, LED defective- re-

• 

place Log

Continued . . .