background image

 

Calidou Electronic Panel Radiator

                                                                                   

Models

CAL075 / CAL100 / CAL150 / CAL200 

Dimensions and Specification 

Model Loading Length 

(A) Height Depth  X 

Z  Weight 

 

(kW) (mm) 

(mm) 

(mm) 

(mm) 

(mm) 

(mm) 

(kg) 

CAL075 0.75 

455 

604  142 140 87 228  17 

CAL100 1.0 

621  604 142 300 87 234  24 

CAL150 1.5 

870  604 142 400 226 242  33 

CAL200 2.0 

1202  604 142 700 227 275  47 

 

 

 

 

 

 

 

 

 

              

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

 

 
                                                                                                                                                              
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

 

Installation and Operating Instructions   

Wall Mounting / Installation 

The heater should be positioned observing the minimum clearances 
stated around the heater. 
(see also ‘Electrical’ section) 
The wall bracket supplied with the heater must be used 

 

1.  Using a screwdriver, turn the latch in a clockwise direction to 
     unlatch the bracket, then remove it from the appliance (see Fig.1) 
2.  Mount the bracket on the wall using a minimum of 4 screws  
     (max diameter 6mm) making sure that it is the correct way up and 
     at the correct height. (see Fig.2) 
3.  Position the appliance on the bracket. 
4.  Re-latch the bracket turning the latch anti-clockwise. 

Electrical 

The wires in the mains lead are coloured in accordance with the following code: 

GREEN & YELLOW       EARTH 
BLUE NEUTRAL 
BROWN LIVE 
BLACK PILOT 

WIRE 

(See also ‘Pilot Wire Connection’) 

The heater is fitted with a length of flexible cable for connection to the fixed wiring of the 
premises through a suitable connection box positioned adjacent to the heater. 
The supply circuit to each heater must incorporate a double pole isolating switch having a 
contact separation of at least 3mm 

 

Pilot Wire Connection 

The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex 
programmers. If, however a programmer is not being used, the pilot wire should be isolated in 
accordance with the current IEE Wiring Regulations. 

IMPORTANT

 - Do 

NOT

 connect the BLACK pilot wire to earth 

Care should be taken with the installation of the pilot wire(s) as when switching to background 
(set back) they become energised at 240V although only at a current of 1mA. 
In every case a suitable means of isolation must be provided for the pilot wire and marked to 
indicate that two sources of supply may be present at the heater. 
Where pilot wires are installed separately from the heater final sub-circuit they should be 
protected, double insulated and carry their own integral earth continuity conductor.  

Model A 

(mm  B 

(mm) 

CAL075 140 

228 

CAL100 300 

234 

CAL150 400 

242 

CAL200 700 

27 

IP24             

Issue 5   November 2004

 

General 

The Calidou radiator is designed to provide exceptional levels 
of comfort  with a combination of radiant and convected heat 
in both domestic and commercial applications.

 

IMPORTANT SAFETY ADVICE 

 

 

When using electrical appliances, basic precautions should always 
be followed to reduce the risk of fire, electrical shock, and injury to 
persons, including the following: 

 

WARNING THE SURFACES OF THIS HEATER CAN BE HOT 
Momentary contact with any part of the heater should not cause 
injury. However, aged or infirm persons or young children should not 
be left unsupervised in the vicinity of the heater unless a suitable 
guard is fitted 

 

IMPORTANT – If this heater is installed in a room containing a bath or 
shower, it should be so installed that switches and other controls 
cannot be touched by a person using a bath or shower – to comply 
with this requirement see ‘Lock the Control Cover’ section on page 2. 

 

If you use this heater in conjunction with an external thermal control, 
a programme controller, a timer or any other device which switches 
the heat on automatically, observe all safety warnings AT ALL TIMES 
since a fire risk exists when the heater is accidentally covered or 
displaced 

 

The installation of this product should be carried out by an electrician 
or competent person and be in strict accordance with the current IEE 
Wiring Regulations and relevant Building Regulations 

 

This heater must not be mounted within 150mm of curtains and other 
combustible materials or 100mm from a shelf or overhang 

 

NEVER cover or obstruct in any way the heat outlet slots at the top of 
the heater or the air inlet slots at the base of the heater 

 

DO NOT cover the heater – Do not place material or garments on the 
heater or obstruct the air circulation around the heater  

 

Before connecting the heater check that the supply voltage is the 
same as that stated on the heater 

 

The heater must be installed in accordance with these instructions 

 

The heater must be mounted using the wall bracket supplied. The 
heater should only be operated in the upright position 

 

The heater should be positioned in accordance to the clearances 
stated in these instructions 

 

DO NOT locate this heater immediately beneath a fixed socket outlet 

Fig.1 

 

Fig. 2

If the wall is a light partition or crumbling, then supporting legs 
are also needed  
(Part No. CAL0001). The heater 

MUST

 be fitted to the wall as 

well as having the supporting legs 

 

 

1. 

Place the legs under the heater 

2. 

Position the hinges into the grooves in the air inlet 

3. 

Unscrew the jacks, until they reach the floor 