Introduction
This heater has been designed for fitting in the space behind the plinth of floor standing kitchen units or other fitted furniture
units. It is recommended that the heater is not installed under cupboards used for storing perishable goods. It can be
accommodated in plinths with a minimum height of 12Omm, and is suitable for cupboards of 500mm width and above.
Installation
The installation of this appliance should be carried out by a competent electrician and be in accordance with the current IEE
wiring regulations.
Before undertaking installation work, ensure the electricity supply is disconnected from any relevant fixed wiring.
The heater is more easily fitted during the installation of new furniture units, or on existing furniture units if they can be
temporarily moved from their position against the wall. If an existing furniture unit cannot be moved, then it may be
necessary to remove the back of the unit in order to gain access to carry out the wiring installation.
Before installing the unit consider the location with respect to the following;
The electrical supply and cable length.
Position heater to deliver heat effectively without causing personal discomfort from overheating while standing at
work surfaces etc.
Minimum plinth height of 120mm and minimum furniture unit width of 500mm.
Procedure
1. Cutting the aperture in the Plinth
Cut aperture in furniture unit plinth to dimensions
shown.
This must be positioned so that the
minimum distance from the bottom of the aperture
to the TOP surface of any floor covering is not
less than 12mm and not more than 25mm.
If an overhang above the heater is greater than
75mm, then a distance of at least 100mm must
be maintained between the overhang and the
uppermost part of the heater.
Note:
If fitted in corner with adjacent cupboards
to left hand side of heater then a distance of at
least 150mm must be maintained between the left
hand end of the heater and the front of the
adjacent cupboard door.
*
This dimension must be maintained above the
top surface of any floor covering material. All
dimensions in millimetres.