Dimplex Bellingham Скачать руководство пользователя страница 1

The product complies with the European Safety Standards EN13229 for Room heaters fired by solid fuel.

Bellingham 4.7kW Multifuel Inset Stove

For Standard 16” Fireplace Opening

Please hand these instructions to the stove user when installation is complete. 

Leave the system ready for operation and instruct the user in the correct use of the 

appliance and operation of controls.

Installation should only be carried out by a suitably qualified installer. 

Dimplex recommend using an installer who is registered with HETAS (UK) or with INFO 

(Republic of Ireland). Installation must comply with all current Building Regulations.

08/52386/0 - Issue 4

25 Nov 2014

Содержание Bellingham

Страница 1: ...r when installation is complete Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of controls Installation should only be carried out by a suitably qualified installer Dimplex recommend using an installer who is registered with HETAS UK or with INFO Republic of Ireland Installation must comply with all current Building Regulations 08 52386...

Страница 2: ...iation 25 4mm 1 Table 2 Technical Specification Bellingham Inset BLM4iSE Wood Solid Fuel Nominal heat output kW 4 7 4 7 Efficiency 81 8 72 8 CO Emission 13 O2 0 24 0 24 Flue Gas Temp C 233 258 Flue Gas Mass Flow g s 3 9 4 4 Refuel Period hr 1 Safe Distance to Combustible Materials mm Top 350mm Sides 150mm Flue Outlet Size mm inch 152 6 Product Weight kg 70 A B H C F E D G K J L Dia 45 2 ...

Страница 3: ...4 5 6 7 3 1 2 6 7 5 4 3 ...

Страница 4: ...ange in flooring level to distinguish hearth Clay Flue pipe Z CONSTRUCTIONAL HEARTH NON COMBUSTIBLE 125mm THICK MINIMUM Z At least 150mm or to a suitably heat resistant wall min 225mm Z non combustible wall min thick Y fireback and insulated infill Fireplace Opening 400mm 16 X X Typical installation C A B ...

Страница 5: ... fire cement glue are caustic and should not be allowed to come into contact with the skin Use suitable protective gloves when handling In case of contact wash immediately with plenty of water Asbestos This appliance contains no asbestos If there is a possibility of disturbing asbestos as a result of installation then specialist guidance must be sought prior to installing Please Note Any white dep...

Страница 6: ...e the stove is level Building Regulations require that a solid constructional hearth of minimum 125mm must be used including the thickness of the floor and any decorative top surface e g tiling The Constructional hearth must extend minimum 225mm in front of the appliance and at least 150mm from either side and the rear of the appliance Fig 10 All walls adjacent to the hearth should be made from so...

Страница 7: ...uced to adjust the stove to the desired heat output If refuelling with solid fuel then the airwash should be closed and the primary air slide should be fully open until the fuel is well alight Once the fuel is well alight the primary air may be adjusted to control the fire to the desired heat setting Do not operate the stove with both air supplies open for extended periods as this will result in o...

Страница 8: ...Do not clean while the stove is hot wait until it has cooled down The finish can be renovated with a suitable brand of stove paint Glass Panels Clean the glass panels when cool with a proprietary glass cleaner or some damp newspaper Do not use abrasive materials as these can scratch the glass and make subsequent cleaning more difficult Wet logs on heated glass a badly aimed poker or heavy slamming...

Страница 9: ...d log retainer It is a condition of the guarantee that the installation complies with relevant Building Regulations and is carried out by a suitably qualified individual HETAS registered in England and Wales or equivalent in other countries with certificate of installation and appropriate commissioning retained by the end user along with proof of purchase Whilst the guarantee does not cover any as...

Страница 10: ... 10 ...

Страница 11: ...0647 0 4 AIRWASH 1 70630 0 16 BAFFLE PLATE 1 70648 0 5 AIRWASH SLIDE 1 70631 0 17 FLUE COLLAR 1 70649 0 6 AIRWASH HANDLE 1 70632 0 18 ASHPAN 1 70651 0 7 DOOR 1 70633 0 19 CLAMP 1 70653 0 8 GLASS 1 70634 0 20 PRIMARY SLIDE HANDLE 1 70818 0 9 GLASS FIXING BRACKET 1 70635 0 21 LOG BAR 1 70819 0 10 DOOR PIN 1 70636 0 22 PROTECTIVE GLOVE 1 71118 0 11 PRIMARY AIR SLIDE 1 70637 0 23 OUTER WRAP ASSEMBLY 2...

Страница 12: ...on SO30 2DF t 44 0 844 879 3588 f 44 0 1489 773050 e aftersales dimplex co uk w www dimplex co uk Northern Ireland Glen Dimplex Northern Ireland 5 Charlestown Avenue Charlestown Industrial Estate Craigavon Co Armagh BT63 5ZF t 44 0 2838 337 317 f 44 0 2838 350 208 e info glendimplexni co uk w www glendimplexni co uk Republic of Ireland Dimpco Ltd Old Airport Road Cloghran Co Dublin Ireland t 353 0...