Select 4 suitable screws (diameter of screw head should be less than 6
mm, diameter of screw should be less than3.5 mm diameter, as shown
in Pic 5) and fix the device on the wall as Pic 6, don’t completely tighten
the screws, keep some space about 2mm.
Install hanging ear of switch alignment inside the four screws, then press
the switch down, ensure the hanging ear has been fix properly, and turn
the screw.
4.3
Wall-mounted installation
Input terminal of the switch for 6PIN plug type terminals, V1+ and V1- is
for power supply 1 (PWR1), V2 + and V2- is for power supply 2 (PWR2)
and GND for earthing terminal, as shown in Pic 7.
Power 1 and power 2 input voltage range is 12VDC ~ 56VDC, V1+, and
V2+ are positive, V1- and V2- are negative, and the equipment supports
anti reverse function; Two sets of power can be simultaneously accessed.
So if one of the power failures, the switch is still able to work.
Pic 7
DC 12~56V
PWR1
PWR2
GND