background image

Th
ref

 

Al

N

2

4

mi

Th
ca

 

mi

Ins
ca

 

 

is guide is f

fer to the Us

l-in-One C

No

 

1 RJ-45 

Power 
(3-pin 

Alarm 
(4-pin 

4 Audio 

5 BNC 

 

icroSD Ca

e positions 

mera’s front

croSD Card

sert the micr

mera is pow

NOTE

suppor
inform

for quick ins

ser’s Manua

Cable         

Cable

 

r (DC 12V / A

Terminal B

I/O 

Terminal B

I/O 

ard Slot / D

of microSD

t housing, pl

d Slot 

roSD card in

wered on.

 

:

 It is not rec

rt long term

ation regard

stalling and 

l of the cam

                 

AC 24V) 

lock) 

lock) 

Default Bu

D card slot a

lease refer t

nto the card 

commended

m continuou

ding the relia

connecting

era in the su

                 

Pin  




A

A

A

A

Green  A

Pink 

A

utton     

and default 

to section m

slot to store

d to record w

s data read

ability and th

 DIGITUS D

upplied CD. 

                 

Defi

For network
DC 12V 

 

Reserved 
DC 12V + 
Alarm In 

 

Alarm In + 
Alarm Out 

Alarm Out +
Audio Out 
Audio In / M
For analog v

                 

button are 

icroSD Card

e videos and

with the micr
d/write. Plea

he life expec

DN-16084-1

                 

nition 

k and PoE co

AC 24V 1
GND 
AC 24V 2

 

Mic In 

video outpu

                 

shown as 

d Slot / Defa

d snapshots

roSD card fo

ase contact 

ctancy. 

 Bullet IP C

                 

 

onnections 

 

Power c

 

Alarm c

Two-wa

                 

below. For 

ault Button in

s. Do not rem

or 24/7 cont

the manuf

B

Camera. For

                 

Rem

connection 

connection 

ay audio tran

                 

details abo

n the User’s

 

move the mi

tinuously, as

facturer of t

Bullet IP

r more detai

                 

marks 

nsmission 

               

ut how to d

 Manual. 

icroSD card

s it may not 

the microSD

P Came

ils, please 

               

 

detach the 

d when the 

be able to 

D card for 

era Quic

     

Default B

Press the

 

Camera

Please fo

 

Power C

Please u
power ou
other end
 

Ethernet

Connect 
cable to 
 

N

P

 

N

c

 
 

 

Before 

A client p
camera, 
plug-ins 
supplied 

 

A

Step 1:
Step 2:

Step 3:

Step 4:

 

Camera

The cam
camera c
detected
the came

 

IP Addre
Subnet M

 

Login ID

 Key in

 Enter 

case s

ck Guid

Button 

e default bu

a Cabling

ollow the ins

Connection

use a DC 12

utlet. Alterna
d of the cab

t Cable Con

one end of 

the network

NOTE:

 In so

PC. 

NOTE

: Chec

check the LA

Green Li
Orange A

Login to t

program wil

please ens

or setting I

CD. 

ActiveX Co

:

  Start the I

Select <T
browser. T

Click the <
and click 
settings.

Set “Activ
<Prompt>

a Login

mera is defa

can be foun

, then the ca

era under fix

ess: 192.168

Mask: 255.2

D and Passw

n the camera

the default u

sensitive.

 

tton with a p

 

 

structions be

2V / AC 24V
atively, conn

le to a Powe

nnection 

the Etherne

k switch or P

ome cases, E

ck the statu

AN connectio

nk Light ind

Activity Light

the Camer

ll be automa

sure downlo

nternet’s se

ntrols and 

nternet Exp

Tools> from 

Then click <
<Security> t

<Custom le

veX controls

 or <Enable

 

 

ault set as D

nd via UPnP

amera would

xed IP addre

8.0.100 

255.255.0 

word 

a’s IP addres

username (

a

proper tool f

 

elow for cab

V adaptor a

nect the Eth

er Sourcing 

et cable to t

PC. 

Ethernet cro

us of the lin

on. 

icates good 

t flashes for 

ra               

atically insta

oading the A
ecurity level 

Plug-ins Se

plorer (IE). 

 the main 
Internet Opt

tab and sele

evel> to cha

s and plug-

e>.

 

 

DHCP mode

P search or 

d switch aut

ess, please s

ss in the UR

admin

) and 

or at least 2

 

     

le connectio

and connect 
hernet cable 

Equipment 

he RJ-45 co

ossover cabl

k indicator a

network co
network act

                 

alled to the 

ActiveX con

to default. 

ettings 

menu of th

tions>. 

ct <Internet>

ange Active

-ins” items t

 

     

e to obtain 

please use 

tomatically t
set the IP ad

RL bar of the

password (

20 seconds t

                 

ons. 

it to the 3-

e to the RJ-4

(PSE) switc

onnector of t

e might be n

and the act

nnection. 
tivity indicat

                 

PC when c

ntrol is allow

For further 

he 

>, 

eX 

to 

Step 1:
Step 2:

 

Step 3:
Step 4:

 
 
 

                 

IP address 

the search 

to fixed IP a
ddress of the

e web brows

admin

) in th

to restore th

                 

pin terminal

45 connecto

ch. 

the All-in-On

needed whe

ivity indicato

ion. 

                 

onnecting to

wed by eithe

details, ple

Inte

  Start the In

 

Select <T
browser. T

  

Click the <

  Down the 

<OK> to c
window, 
accessing 

                 

from the D
tool from th

ddress unde

e PC as: 19

ser window a

he prompt re

e system.

                 

l block of th

or of the All-

ne cable, an

en connectin

or LEDs. If 

                 

o the camer

er changing

ease refer to

ernet Secu

nternet Expl

Tools> from
Then click <I

<Security> ta

page, click

confirm the s

and open 
 the IP came

                 

DHCP serve

he CD. How
er 

192.168.0

92.168.0.XXX

and hit on “E
equest dialo

               

he All-in-One

in-One cabl

nd plug the o

g the camer

the LEDs a

                 

ra. Before lo

g the Active
o the User’s

rity Level

orer (IE). 

the main 

nternet Opt

ab and selec

“Default Le

setting. Clos

a new o

era.

 

                 

r. Under DH

wever if no D

0.250

. There

X; for examp

Enter”.  

gue. Note th

               

e cable and

le, and plug

other end of

ra directly to

are unlit, ple

               

ogging in to

eX controls 

s Manual in

menu of t

tions>. 

ct <Internet>

evel” and cl
se the brows
one later 

                 

HCP mode,

DHCP serve
efore, to acc
ple: 

hat usernam

 

     

 the 
 the 

f the 

o the 

ease 

               

 the 

and 

the 

the 

>. 

ick 

ser 

for 

           

 

the 

er is 

cess 

me is 

Отзывы: