4. At the Main menu, select
Calibration
and then
1PT CAL
(1-point calibration).
Receiver Calibration Screen
5. Use a tape measure to ensure the distance from the center of the transmitter to the inside edge of
the receiver is 10 ft. as shown below, then click to begin the calibration.
1.
Trigger click prompt (flashes)
Calibration Prompt
If you wait longer than about 15 seconds to click the trigger, the calibration terminates and the Above
Ground Range (AGR) screen displays (see next section).
6. The display counts down to zero while the receiver records the calibration point. Do not move the
receiver.
7. A successful calibration yields a check mark above the transmitter icon and four beeps. An
unsuccessful calibration yields an
X
above the transmitter icon and two beeps.
Successful
Unsuccessful Unsuccessful