Volume Pedal Update
The GNX1 provides the option of selecting the Expression Pedal’s position to be updated after changing Presets
when it is linked to the Volume Parameter. This feature allows you to change Presets and retain the same volume
level from the previous Preset if the Expression Pedal is assigned to control volume on both Presets. If this feature is
disabled, new Presets will initialize at the volume level value stored to the Preset.The procedure for enabling or dis-
abling the Volume Pedal Update is as follows:
1. Press the Utility button once.The LED in the Utility button will light indicating you are in the Utility section.
2. Using the FX Mode or Rhythm button, scroll to the left or right until the Display shows
vOLUPD
(Volume
Pedal Update).
3. Press the Data Up/Down to select
On
(enabled), or
OF
(disabled).
4. Press the Exit button to return to the GNX1 Presets.
V-Switch Threshold
Applying extra pressure on the toe of the Expression Pedal engages a feature we call the V-Switch.The V-Switch is
used to alternate between the Expression Pedal controlling the assigned Parameter(s), and acting as a Wah Pedal.The
sensitivity of the V-Switch can be tailored to engage with the amount of pressure you wish to use.
The following steps outline the procedure for adjusting the V-Switch threshold:
1. Press the Utility button once.The LED in the Utility button will light indicating you are in the Utility section.
2. Using the FX Mode or Rhythm button, scroll to the left or right until the Display shows
vSWICH
(V-Switch).
3. Press the Data Up/Down to select the threshold setting you desire. Ranges from
1
to
99
(with 99 requiring
more pressure to engage).The sensitivity may be auditioned while making adjustments.The Display will read either
WAH ON
, or
WAHOFF
(depending on the status of the Wah) as the V-Switch engages and disengages.
4. Press the Exit button to return to the GNX1 Presets.
Expression Pedal Calibration
The Expression Pedal on the GNX1 needs to be recalibrated for use after a factory reset has been performed.This
calibration procedure is automatically entered after a factory reset procedure. In the event the Pedal’s calibration
fails, or if the Pedal does not function properly, it can be re-calibrated using the Pedal Calibration menu.The proce-
dure for Calibrating the Expression Pedal is as follows:
1. Press the Utility button once.The LED in the Utility button will light indicating you are in the Utility section.
2. Using the FX Mode or Rhythm button, scroll to the left or right until the alpha-numeric Display shows
PDLCAL
(Pedal Calibration).
3. Press the blinking Store button once to enter the Pedal Calibration Menu.The alpha-numeric Display reads
TOE DN
(Toe Down).
4. Rock the Expression Pedal all the way forward to the toe down position and press the blinking number 2
Footswitch.The Display changes to read
TOE UP
(toe up).
5. Rock the Expression Pedal all the way back to the toe up position and press the blinking number 3
Footswitch.The Display will show
VSWTCH
and allow you to adjust the V-Switch threshold.
6. Rock the Expression Pedal forward and apply the desired V-Switch pressure to the toe of the pedal. If further
adjustment to the threshold is required, use the Data Up/Down buttons to select the desired threshold.
Note: If the Display shows
ERROR
, an error has occurred and steps 2 through 5 should be repeated.
7. Press the Exit button to return to the GNX1 Presets.
35
S
ECTION
F
IVE
- O
THER
F
UNCTIONS