LISTED COMPLIANCE SPECIFICATIONS
The programming and installation specifications contained in this section must be completed when installing the
XTLplus Series panel in accordance with any of the ANSI/UL or SIA burglary standards. Additional specifications may
be required by a particular standard.
Use Marking
Commercial Central Station, Household Burglar Control Unit.
Locations and Wiring
Locations and wiring methods shall be in accordance with the National Electrical Code, ANSI/NFPA 70 and the
Standard for Installation and Classification of Burglar and Holdup Alarm Systems, UL 681.
NFPA 72
This equipment should be installed in accordance with Chapter 29 of the National Fire Alarm Code, ANSI/NFPA 72,
(National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). Printed information describing proper
installation, operation, testing, maintenance, evacuation planning, and repair service is to be provided with this
equipment.
Warning:
Owner’s instruction notice, not to be removed by anyone except occupant.
Types Of Service
Suitable for Central Station Burglar. Suitable for Household Fire and Household Burglar. Test weekly.
Police Station Phone Numbers
The XTLplus must not be programmed to communicate with a police station.
Bypass Reports
The bypass reports must be programmed as YES for all listed burglary applications.
System Testing
The system must be tested once per week and checked by a qualified technician once every three (3) years.