XTLplus Series Installation and Programming Guide | Digital Monitoring Products
33
AREA INFORMATION
Area Information
This section allows you to assign functions to individual areas for XTLplus Series
panels. All non-24-hour zones must be assigned to an active area.
Activate an area by assigning it a name. An area can be armed or disarmed. A name is
given to each active area to assist the user during arming and disarming.
Area Number
Enter the number of the area to program. In an area system, select from areas 1 to 6.
In an All/Perimeter system, select INT (interior) or PERIM (perimeter).
In a Home/Away system, select INT (interior), BDRM (bedroom), or PERIM
(perimeter).
Area Name
In an area system, enter up to 16 characters for the area name. Only those areas given
names can have zones assigned to them. All others are marked UNUSED.
To add an area name to the system, press any Select Key or Area and then enter up to
16 characters for the new name. Refer to
To mark an active area as unused, delete the old name by pressing any Select Key or
Area then press CMD. The panel automatically sets the name as UNUSED.
Automatic Arming
Select YES to allow this area to arm automatically according to the opening and
closing schedule.
If Closing Check is selected as YES, the automatic arming does not take place until
the expiration of a 10-minute Closing Check delay. If the area has been disarmed
outside a schedule and the area was forgotten to be armed again, the Closing Check
delay occurs one hour after the area is disarmed.
At arming, faulted zones are handled according to the option selected in Bad Zones.
Select
NO
to disable automatic arming for this area. Default is
NO
.
Bad Zones
At the time of automatic arming, some zones in the area may not be in a normal
condition. This option allows you to program the panel’s response to these bad zones.
This option is not displayed if AUTO ARM is NO.
BYP: All bad zones are bypassed. A report of the bypass is sent to the receiver if
Bypass Reports has been selected as YES. See
. The report indicates
SCH as the user number.
FORC: All bad zones are force armed. Zones force armed in a bad condition are
capable of restoring into the system and reporting alarms if tripped. A report of the
force arm is sent if Bypass Reports is YES. See
. The report indicates
the user number as SCH.
REF: The automatic arming is refused and no arming takes place. A No Closing
report is sent to the receiver regardless of the Closing Check selection. For listed
installations, set Bad Zones to REF.
Automatic Disarming
NO
disables automatic disarming by schedule for this area. Select YES to allow this
area to automatically disarm according to a schedule. If an Opening report is sent to
the receiver, the user number is indicated as SCH. Default is
NO
.
AREA INFORMATION
AREA NO: -
INT
PERIM
INT BDRM PERIM
* UNUSED *
AUTO ARM
NO
YES
BAD ZONES:
BYP
BYP FORC REF
AUTO DIS
NO
YES