XTLplus Series Installation and Programming Guide | Digital Monitoring Products
32
OUTPUT SETUP
Output Setup
This section allows you to program and name wireless outputs into the panel.
Output Number
Enter an output number. Select from the following output numbers:
▶
51 to 54 - Slow response time* wireless outputs (activate within 15 seconds)
▶
61 to 64 - Fast response time* wireless outputs (activate within 1 second)
Note:
Addresses 51 to 54 and 61 to 64 are available for wireless outputs or
wireless key fob zones and can only be assigned to one device.
* The response time of a wireless output is the time it takes for a wireless output
to activate once the panel event occurs. A slow response output number extends
battery life, but response time may be up to 15 seconds. A fast response output
number responds within 1 second, but reduces battery life. Refer to the specific
wireless output installation guide to determine battery life.
Output Name
This section allows you to define a 16-character alphanumeric name for any wireless
output.
An output that is not part of the system must be marked UNUSED. To mark an output
unused, press any Select Key or Area to display the default name, then press
CMD
.
The programmer automatically programs the name as UNUSED.
Serial Number
Enter the 8-digit serial number found on the wireless device.
ALREADY USED
displays when the serial number is already programmed for another
output or zone. The programmed output or zone number displays.
Supervision Time
Press any top row key to select the supervision time required for the wireless output.
Default is
240
minutes.
Select the required number of minutes. The transmitter must check in at least
once during this time or a missing condition is indicated for that zone. 1100 Series
transmitters automatically check in based on the supervision time selected for
the wireless zone, no additional programming is needed. Zero (0) indicates an
unsupervised transmitter.
The 3-minute supervision time is only available if using an 1135 Wireless Siren.
Note:
When the panel is reset, a receiver is installed or powered down and
powered up, or programming is complete, the supervision timer restarts for all
wireless outputs.
Trip with Panel Bell Option
This option displays when the wireless device is an 1135 wireless siren. Select
YES
to
have the 1135 wireless siren follow the panel bell output. Default is
YES
.
OUTPUT SETUP
OUTPUT NO: -
* UNUSED *
SERIAL#: -
ALREADY USED: ZXX
SUPRVSN TIME:
240
0 3 60
240
TRIP WITH PANEL
BELL
NO
YES