Digital Monitoring Products, Inc. | Z-5010T Installation and Programming Guide
19
2nd Stage Cool Enable
Enables the second stage cooling operation.
•
Y
2nd stage cooling enabled.
•
N
(default)
2nd stage cooling disabled.
Minimum Run Time (MRT)
Set the minimum delay before a heating or cooling cycle can
turn off Range 1 - 9 minutes. Default is
3
minutes.
Minimum Off Time (MOT)
Set the minimum delay before a heating or cooling cycle can
turn off Range 5 - 9 minutes. Default is
5
minutes.
Heat Setpoint Max
Set the maximum heating setpoint value. Range
is 55 °F to 90 °F (4 °C to 43 °C). Default is
90
°F (
32
°C).
Cool Setpoint Min
Set the minimum cooling setpoint value. Range
is 60 °F to 95 °F (6 °C to 45 °C). Default is
60
°F (
15
°C).
Heat Blower Off Delay
Set the system blower delay off time after a heat call ends (fan
purge).
2ND STAGE COOL
ENABLE
MINIMUM RUN TIME
MINIMUM OFF TIME
HEAT SETPOINT MAX
COOL SETPOINT MIN
HEAT BLOWER OFF
DELAY