Default Settings
The thermostat is defaulted to the following typical HVAC system configuration:
•
System type: Standard (gas/electric)
•
Fan type: Gas
•
Heating stages: One
•
Cooling stages: One
Minimum Off Time (MOT)
The thermostat has a Minimum Off Time (MOT) delay after any heating or cooling cycle
ends. A MOT delay prevents rapid heating/cooling cycles and also provides short cycle
protection for the system compressor. This delay may be noticeable when you change
a setpoint and the system doesn’t respond immediately because of the delay timer. For
more information, refer to “Advanced Settings”.
Minimum Run Time (MRT)
The thermostat has a delay after the start of any heating or cooling call. This feature is
called Minimum Run Time (MRT) and ensures even heating and cooling cycles. The MRT
will keep the system on until it expires, even if it reaches the setpoint room temperature
or if the user changes the setpoint to a temperature that would satisfy the call. Changing
the Mode to OFF will cancel the MRT and the system will turn off immediately. For more
information, refer to “Advanced Settings”.