Содержание DEC FDDIcontroller 700

Страница 1: ...993 10 21 52 Document copyright Last saved on Mon Feb 22 1993 10 48 26 Document toc Last saved on Thu Feb 4 1993 15 03 40 Document safety Last saved on Thu Jan 21 1993 10 34 48 Document preface Last s...

Страница 2: ...Order Number EK DEFZA IN D01 DEC FDDIcontroller 700 Installation...

Страница 3: ...UTION This equipment is in the 1st Class category information equipment to be used in commercial and or industrial areas and conforms to the standards set by the Voluntary Control Council for Interfer...

Страница 4: ...ZA IN D01 DEC FDDIcontroller 700 Installation February 1993 This manual describes how to install and verify the operation of the DEC FDDIcontroller 700 controller Supersession Update Information This...

Страница 5: ...quipment Corporation assumes no re sponsibility for any errors that may appear in this document Copyright 1993 by Digital Equipment Corporation All Rights Reserved Printed in U S A The following are t...

Страница 6: ...for Installation 2 2 2 3 Installing the Controller 2 3 2 4 Connecting the Communications Cables 2 5 2 4 1 Connecting ST type Connectors 2 5 2 4 2 Connecting ThinWire and STP Connectors 2 6 3 Verifying...

Страница 7: ...re Problems 4 3 A Related Documents Index Figures 1 1 Controller Components 1 2 1 2 Connecting the Controller to the FDDI Network 1 3 1 3 Contents of Shipping Package 1 4 2 1 Media Selection Switch 2...

Страница 8: ...beachtet werden m ssen um den Benutzer vor Schaden zu bewahren Achtung Enth lt Informationen die beachtet werden m ssen um die Ger te vor Schaden zu bewahren Danger Signale les informations destin es...

Страница 9: ...ein Glasfaserkabel oder einen Glasfaseranschlu Die Laserstrahlen in faser optischen Ger ten k nnen Augenverletzungen verursachen DANGER Certains quipements utilisant les fibres optiques peuvent mettr...

Страница 10: ...nschette und eine geerdete Arbeitsunterlage wenn Sie am offenen Ger t arbeiten ATTENTION Les charges excessives d lectricit statique peuvent en dommager les modules et les composants lectroniques Digi...

Страница 11: ...o has some technical background installing system hardware Structure of This Manual This manual has four chapters and an appendix as follows Chapter 1 Provides an overview and description of the DEC F...

Страница 12: ...e in a command format In an example enter the characters in lowercase Key Indicates that you press the specified key For example Return means that you press the Return key Ctrl x Indicates that you ho...

Страница 13: ...ntroller is called the DEC FDDIcontroller 700 or controller 1 1 Overview The DEC FDDIcontroller 700 and the DEC FDDIcontroller 700 C both consist of two circuit cards in a piggyback configuration with...

Страница 14: ...roller 700 Installation Figure 1 1 Controller Components ThinWire LED STP connector STP LED ThinWire connector Media selection switch LKG 7455 93I LED ST type connector DEC FDDIcontroller 700 DEC FDDI...

Страница 15: ...lectronic components Digital recommends using a grounded an tistatic wrist strap and a grounded work surface when handling any modules The controller is shipped in one box see Figure 1 3 for contents...

Страница 16: ...controller 700 Installation Figure 1 3 Contents of Shipping Package DEC FDDIcontroller DEC FDDIcontroller 700 DEC FDDIcontroller 700 C Screws LKG 7457 93I DEC FDDIcontroller 700 Installation manual th...

Страница 17: ...Installing the controller 4 Connecting the communications cable NOTE If you are installing the controller in a VAX 4000 Mod el 60 or Model 90 unit you first need to install an adapt erforyourDECFDDIco...

Страница 18: ...g setting STP Media selection switch 2 2 Preparing the Computer for Installation To prepare the computer for installation you need a Phillips head screwdriver and an antistatic wrist strap kit Perform...

Страница 19: ...d work surface when handling any modules 1 Attach one end of the antistatic wrist strap to your wrist and the other end to the computer 2 Hold the controller by the edges and position it so that it is...

Страница 20: ...lon pins and make sure the clips snap in place 6 Insert the two screws which held the option slot cover on into the back of the computer to hold the controller in place see Figure 2 3 7 Remove the ant...

Страница 21: ...erform the following steps see Figure 2 4 1 Remove the dust caps from the ST type connectors 2 Line up the transmit cable connector with the transmit port Insert and turn the connector to lock it in p...

Страница 22: ...mit cable connector Receive cable connector 2 4 2 Connecting ThinWire and STP Connectors ToattachThinWire or STP connectors to the controller performoneofthefollowing see Figure 2 5 To attach a ThinWi...

Страница 23: ...r 2 7 Figure 2 5 Example of Connecting the ThinWire and STP Connectors REV XX99 DEFZA CA PHY1 PHY2 DEC FDDIcontroller 700 C LKG 7460 93I ThinWire LED ThinWire connector STP LED STP connector ThinWire...

Страница 24: ...tions connection 3 1 Performing Self test TurningonthepowerforAlphaAXPandMIPssystemsstartsthecontrollerself test When self test completes the PHY LED on the controller will be OFF indicating the contr...

Страница 25: ...ddi 08 00 2b 17 C5 FF 0 PMAG BA DEC V5 1a TCF0 cfb d 8 In this example the controller PMAF AA is in option slot 2 and has a physical ad dress of 08 00 2b 17 C5 FF If the controller is listed go to Sec...

Страница 26: ...n display refer to Section 3 2 1 1 for problem solving information 3 2 3 Verifying and Testing a Configuration Based on a VAX System To verify and test configuration based on a VAX system perform the...

Страница 27: ...t phycsr t mac TFL elm test failed PMAF AA t cam t nirom t intlpbk t iplsaf t pmccsr t rmc t pktmem t botim t rtostim t extlpbk t extmemtst t dmatst TFL elm test failed PMAF AA is an error message and...

Страница 28: ...system documentation for instructions on how to perform this After booting check that the controller PHY LED is ON STEADY GREEN indicating a LINK AVAILABLE state if connected to network If the LED is...

Страница 29: ...D OFF Controller not enabled LED or controller broken Check the console for error mes sages Refer to the list of error messages in Section 4 1 1 Contact your Digital Services rep resentative LED stead...

Страница 30: ...ed PMAF AA TFL iplsaf test failed PMAF AA TFL pmccsr test failed PMAF AA TFL rmc test failed PMAF AA TFL pktmem test failed PMAF AA TFL botim test failed PMAF AA TFL rtostim test failed PMAF AA TFL ex...

Страница 31: ...solutions to a number of hardware problems Be sure that the controller is inserted tightly in its slot and that anything con nected to it is connected correctly If you have another controller that wo...

Страница 32: ...grade DECbridge 500 Series and DECbridge 600 Series units Fiber Distributed Data Interface System Level Description Order No EK DFSLD SD This manual describes the FDDI system how it works and the role...

Страница 33: ...6 Controller description 1 1 Controller kit contents 1 3 D Diagnostics 4 1 E Error messages 4 1 4 2 F FDDI 1 1 FDDI network connection to 1 3 H Hardware problems 4 3 I Installation connecting the cabl...

Страница 34: ...1 S Self test performing 3 1 Self test 4 1 Static electricity 1 3 2 3 T Test display 4 1 Troubleshooting 4 1 TURBOchannel 1 1 V Verifying system configuration 3 2 based on Alpha AXP 3 3 based on MIPs...

Страница 35: ...anada K1G 4C2 Attn A SG Business Manager INTERNATIONAL DIGITAL EQUIPMENT CORPORATION A SG Business Manager c o Digital s local subsidiary or approved distributor Internal orders should be placed throu...

Страница 36: ...ctions were most helpful _________________________________ _________________________________________________________________________________ Did you use the appendices Which ones _____________________...

Страница 37: ...NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY LABEL FIRST CLASS PERMIT NO 33 MAYNARD MASS POSTAGE WILL BE PAID BY ADDRESSEE Telecommunications and Networks Publications 550 King Street Litt...

Страница 38: ...Printed in U S A...