6-15
Chapter 6 - Initializing the GP
GP-2401/2501/2601 Series User Manual
Touch operation and Force Reset setup, and Display Device adjustments are made
here. There may be differences on these settings depending on the GP type.
TOUCH OPERATION MODE
Designates either One Point, Two Point or No Slide. When No Slide is selected,
dragging one's finger across the touch screen creates no screen response and only
individually selected points will register.
FORCE RESET
Designates whether or not a FORCE RESET is performed.
To Display the Menu Bar
While holding down the bottom right corner (1) of the screen, press the upper
right corner (2). At the same time, press the bottom left corner (3) to enter the
FORCE RESET mode. To activate Reset, press the
RESET
button, and to change
to OFFLINE Mode, press
OFFLINE
.
6.4.3 SET UP TOUCH PANEL
!!!!!
You can perform FORCE RESET in either RUN mode or OFFLINE mode.
•
While the GP is starting up, the Menu Bar will not display.
•
Entering SYSTEM RESET is possible even when the PLC and GP are not commu-
nicating.