Chapter 3 - Installation and Wiring
3-14
GP-2401/2501/2601 Series User Manual
3.5
Attaching the Screw Lock Terminal Block
Using the AUX Input/Output I/F requires the separately sold Screw Lock Terminal
Block. Use the procedures shown below to attach the Screw Lock Terminal Block to
your GP unit's AUX I/O I/F.
1) Loosen the set screws of each desired
Screw Lock Terminal Block pin.
2) Insert each wire end into its pin and
tighten the set screw.
Wire Gauge:AWG 16 to AWG 28
Removed Wire Length: 7 +/- 0.5mm
[0.28 +/-0.02 in.]
Torque: 0.2 to 0.4 N•m
(The illustrations below show the procedures for the GP-2501/2601 Series models.
However, these procedures are also the same for the GP-2401 Series.)
3) Re-insert the Terminal Block into the
AUX I/O I/F.
4) Raise both of the Terminal Block's right
and left side clamp levers to secure the
Terminal Block to the AUX I/O I/F.