![Digiplex EVO192 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/digiplex/evo192/evo192_installation-manual_2497782021.webp)
EVO Control Panel
17
When option [8] is enabled, access is permitted during the programmed
holidays (see
7.12 Auto-Arming Options
(default =
disabled
) When using the Auto-Arming features (see
and
), the control panel can Force arm or Stay arm the
partitions. To Auto-Arm using Stay arming, enable option
[3]
in the desired
section:
7.13 Switch To Stay Arming
If no Entry Delay zones are opened and closed during the Exit Delay after
Regular arming a partition, the control panel can switch from Regular
arming to Stay arming. Enable the option in the desired section:
7.14 Always Force Arm when Regular Arming
(default =
disabled
) When enabled for a particular partition, the system will
Force arm that partition whenever Regular or Force arming is activated.
Stay and Instant arming are not affected by this feature. An event will be
generated for every zone bypassed in that manner. Another event will be
generated when the zone will be closed. Enable option
[8]
in the desired
section:
7.15 Auto Force on Stay Arming
(default =
disabled
) When enabled for a particular partition, the system will
Force arm that partition whenever Stay arming is activated. An event will be
generated for every zone bypassed in that manner. Another event will be
generated when the zone will be closed. Enable option
[4]
in the desired
section
7.16 Follow Zone Switches to Entry Delay 2
(default =
enabled
) When enabled and an Entry Delay zone is bypassed,
an armed Follow Zone (see
on page 10) that opens without an
Entry Delay being triggered will switch to the partition’s Entry Delay 2.
Enable option
[8]
in the desired section:
7.17 One-Touch Features
(default =
disabled
) The One-Touch features can arm or disarm a partition,
access Bypass Programming, or display the Event Buffer by pressing and
holding a specific key for 2 seconds instead of entering an access code. If
the keypad is assigned to more than one partition, the feature must be
enabled in the corresponding partitions. Select the section corresponding to
the desired partition and enable or disable the desired options:
7.18 Exit Delay
(default =
060
) The Exit Delay is the amount of time users have to leave the
protected area before arming. It applies to all zones, except 24Hr Zones.
Program the Exit Delay from 001 to 255 seconds:
7.18.1 Exit Delay Termination
(default =
enabled
) The control panel can reduce the Exit Delay to 7
seconds when an Entry Delay zone is opened and closed during the delay.
Enable option
[4]
in the desired section:
7.18.2 No Exit Delay on Remote Arm
(default =
enabled
) When a user arms by using a remote control from the
Magellan Wireless System (MG-RTX3), the control panel will cancel the
Exit Delay and immediately arm the partition. Enable option
[8]
in the
desired section:
7.18.3 Special Arming Exit Delay
(default =
060
) This allows to set an exit delay in seconds for a special
arming. Special arming are any arming that do happen without interacting
with a keypad (i.e.: scheduled arming, keyswitch arming, WinLoad arming,
no movement arming, etc.)
7.19 Keypad Lock-out Feature
(default =
005
) If a consecutive number of invalid codes are entered into a
keypad, the control panel can be set to lockout access from all the keypads
in the partition for a specified period. Program the number of consecutive
invalid codes from 001 to 255 (000 = disabled) into the desired section:
No Movement Schedule
Partition 1:
[3131]
Partition 3:
[3331]
Partition 5:
[3531]
Partition 7:
[3731]
Partition 2:
[3231]
Partition 4:
[3431]
Partition 6:
[3631]
Partition 8:
[3831]
Option
Day
Option
Day
[1]
Sunday (S)
[5]
Thursday (T)
[2]
Monday (M)
[6]
Friday (F)
[3]
Tuesday (T)
[7]
Saturday (S)
[4]
Wednesday (W)
[8]
Holidays (H)
Partition 1:
[3122]
Partition 3:
[3322]
Partition 5:
[3522]
Partition 7: [
3722]
Partition 2:
[3222]
Partition 4:
[3422]
Partition 6:
[3622]
Partition 8:
[3822]
Partition 1:
[3121]
Option
[1]
Partition 5:
[3521]
Option
[5]
Partition 2:
[3221]
Option
[2]
Partition 6:
[3621]
Option
[6]
Partition 3:
[3321]
Option
[3]
Partition 7:
[3721]
Option
[7]
Partition 4:
[3421]
Option
[4]
Partition 8:
[3821]
Option
[8]
Partition 1:
[3123]
Partition 3:
[3323]
Partition 5:
[3523]
Partition 7:
[3723]
Partition 2:
[3223]
Partition 4:
[3423]
Partition 6:
[3623]
Partition 8:
[3823]
Partition 1:
[3126]
Partition 3:
[3326]
Partition 5:
[3526]
Partition 7:
[3726]
Partition 2:
[3226]
Partition 4:
[3426]
Partition 6:
[3626]
Partition 8:
[3826]
Partition 1:
[3122]
Partition 3:
[3322]
Partition 5:
[3522]
Partition 7:
[3722]
Partition 2:
[3222]
Partition 4:
[3422]
Partition 6:
[3622]
Partition 8:
[3822]
Partition 1:
[3125]
Partition 3:
[3325]
Partition 5:
[3525]
Partition 7:
[3725]
Partition 2:
[3225]
Partition 4:
[3425]
Partition 6:
[3625]
Partition 8:
[3825]
Option One-Touch Feature
One-Touch
Key
[1]
Regular Arming
[
ARM
]
[2]
Stay Arming
[
STAY
]
[3]
Instant Arming
[5]
[4]
Force Arming
[
FORCE
]
[5]
Stay/Instant Disarming
[
DISARM
]
[6]
Bypass Programming
[
BYP
]
[7]
Event Record Display
[7]
Partition 1:
[3108]
Partition 3:
[3308]
Partition 5:
[3508]
Partition 7:
[3708]
Partition 2:
[3208]
Partition 4:
[3408]
Partition 6:
[3608]
Partition 8:
[3808]
Partition 1:
[3122]
Partition 3:
[3322]
Partition 5:
[3522]
Partition 7: [
3722]
Partition 2:
[3222]
Partition 4:
[3422]
Partition 6:
[3622]
Partition 8:
[3822]
Partition 1:
[3125]
Partition 3:
[3325]
Partition 5:
[3525]
Partition 7:
[3725]
Partition 2:
[3225]
Partition 4:
[3425]
Partition 6:
[3625]
Partition 8:
[3825]
Partition 1:
[3130]
Partition 3:
[3330]
Partition 5:
[3530]
Partition 7:
[3730]
Partition 2:
[3230]
Partition 4:
[3430]
Partition 6:
[3630]
Partition 8:
[3830]
Partition 1:
[3105]
Partition 3:
[3305]
Partition 5:
[3505]
Partition 7:
[3705]
Partition 2:
[3205]
Partition 4:
[3405]
Partition 6:
[3605]
Partition 8:
[3805]