Entering section [020] will activate the PGM for 8 seconds to verify if the
PGM is functioning properly.

The value programmed in section [002] represents how long the Power
Supply Module will wait before reporting an AC power failure to the control
panel. To program the timer, enter a 3-digit decimal value (000 to 255
minutes) into section [002]. 

Default: Instant reporting (000).

S

PECIFICATIONS

AC Power:

16Vac, 20/40VA, 50 - 60Hz

Aux. Power:

12Vdc, typical 600mA, 700mA max.

Battery:

12Vdc, 4Ah minimum

Number of Outputs:

1 form “C” relay rated @ 125V, 5A receptive load

Control Panel 
Compatibility:

Any Digiplex (DGP-48) or DigiplexNE (DGP-NE96)

Section [020]

PGM Test Mode

Section [002]

AC Failure Report Delay

Figure 1: Connecting the DGP2-PS17