DGP-641 LCD Keypad V1.3
Programming Guide
P
ROGRAMMING
M
ETHOD
To view the keypad’s serial number, press and hold the
[0]
key,
then enter the
[
INSTALLER
CODE
]
and enter
[000]
. We recommend
that you use this sheet to keep track of which sections were
programmed and how. This module can also be programmed using
the control panel’s Broadcast Programming Feature (see
Digiplex
Installation & Reference Manual
).
P
ROGRAMMING
S
ECTIONS
In the following tables and sections, any value represented in
bold
is the default setting.
SECTION [006]
Confidential Mode Timer (005-255 seconds)
___/___/___ (default = 120)
SECTION [007]
PGM Timer (000-255
see option [3] in section [005]
)
___/___/___ (default = 005)
SECTION [008]
PGM Activation Event:
PGM Table in Digiplex Programming Guide
___/___ [1 2 3 4 5 6 7 8] (default = 0 / 0 all off)
SECTION [009]
PGM Deactivation Event:
PGM Table in Digiplex Programming Guide
___/___ [1 2 3 4 5 6 7 8] (default = 0 / 0 all off)
M
ESSAGE
P
ROGRAMMING
Each section from
[101]
to
[249]
contains one message with a
maximum of 16 characters. For more details and to record any
changes, use the
DGP-641 LCD Programming Guide
.
Section
[101]
to
[148]
= Zone 01 to Zone 48 respectively
Section
[149]
to
[244]
= Code 01 to Code 96 respectively
Section
[245]
= Paradox Family
Section
[246]
to
[249]
= First, Second, Third, & Fourth Area
After entering the section corresponding to the desired message,
the message can be re-programmed to suit your installation needs
as detailed in Table 1. For example, section [101]
“ZONE 01”
can
be changed to
“FRONT DOOR”
.
STEP 1: Press and hold the
[0]
key
STEP 2: Enter the
[
INSTALLER
CODE
]
STEP 3: Enter section
[953]
STEP 4: Enter the keypad’s 8-digit
[
SERIAL
NUMBER
]
STEP 5: Enter the 3-digit
[
SECTION
]
you want to program
STEP 6: Enter the required data
SECTION [001]: Partitioning
Option
OFF
ON
[1]
Partition 1
l
Disabled
l
Enabled
[2]
Partition 2
l
Disabled
l
Enabled
[3]
Partition 3
l
Disabled
l
Enabled
[4]
Partition 4
l
Disabled
l
Enabled
[5]
Not used
l
N/A
l
N/A
[6]
Not used
l
N/A
l
N/A
[7]
Not used
l
N/A
l
N/A
[8]
Not used
l
N/A
l
N/A
SECTION [002]: General Options
Option
OFF
ON
[1]
Display Code Entry
l
Disabled
l
Enabled
[2]
Display Exit Delay
l
Disabled
l
Enabled
[3]
Display Entry Delay
l
Disabled
l
N/A
[4]
Confidential Mode
l
Disabled
l
Enabled
[5]
To Exit Confidential Mode
l
Enter Code
l
Press Button
[6]
Not used
l
N/A
l
N/A
[7]
Not used
l
N/A
l
N/A
[8]
Not used
l
N/A
l
N/A
SECTION [003]: General Options
Option
OFF
ON
[1]
Muting
l
Disabled
l
Enabled
[2]
Exit Delay Beep
l
Disabled
l
Enabled
[3]
Not used
l
N/A
l
N/A
[4]
Chimed Zone Closure
l
Disabled
l
Enabled
[5]
Not used
l
N/A
l
N/A
[6]
Not used
l
N/A
l
N/A
[7]
Not used
l
N/A
l
N/A
[8]
Not used
l
N/A
l
N/A
SECTION [004]: Beep on Trouble
Option
OFF
ON
[1]
System & Clock Trouble Beep
l
Disabled
l
Enabled
[2]
Communicator Trouble Beep
l
Disabled
l
Enabled
[3]
Module & Bus Trouble Beep
l
Disabled
l
Enabled
[4]
All Zone Trouble Beeps
l
Disabled
l
Enabled
[5]
Not used
l
N/A
l
N/A
[6]
Not used
l
N/A
l
N/A
[7]
Not used
l
N/A
l
N/A
[8]
Not used
l
N/A
l
N/A
SECTION [005]: PGM Options
Option
OFF
ON
[1]
PGM State is Normally
l
Open
l
Closed
[2]
PGM Timed Mode
l
Disabled
l
Enabled
[3]
PGM Base Time
l
1 Second
l
1 Minute
[4]
PGM Override
l
Disabled
l
Enabled
[5]
Keypad Tamper
l
Disabled
l
Enabled
[6]
Not used
l
N/A
l
N/A
[7]
Not used
l
N/A
l
N/A
[8]
Not used
l
N/A
l
N/A