background image

 

1300 Henley Court 

Pullman, WA 99163 

509.334.6306 

www.digilentinc.com 

PmodENC

™ Reference Manual

 

 

Revised January 20, 2016 
This manual applies to the PmodENC rev. A 

 

DOC#: 502-117 

Copyright Digilent, Inc. All rights reserved. 

Other product and company names mentioned may be trademarks of their respective owners.

 

Page 

1

 of 

3

 

 

 

Overview  

The Digilent

 

PmodENC

 

features a rotary shaft encoder with an integral push-button to provide multiple types of 

outputs. The module also includes a sliding switch that is commonly used as an on/off output. An encoder is 
commonly used in freely rotating volume knobs to detect how many “clicks” a knob has been rotated. 

 

Functional Description 

The PmodENC utilizes a rotary shaft encoder as a way for users to quickly switch between multiple options such as 
choices shown on a screen or predefined motors speeds. An integral push-button on the shaft as well as a slide 
switch allow for a highly configurable Pmod. 

 

Interfacing with the Pmod 

The PmodENC communicates with the host board via the

 

GPIO protocol. It provides four inputs to the system 

board; the two buttons internal to the encoder that are in quadrature with each other as well as the integral push 
button on the shaft and the slide switch. A system board will read the integral push button and the slide switch at 
a logic low voltage in their native (or off in the case of the switch) states. 

 

 

The PmodENC. 

 
 
 

 

Rotary push-button shaft encoder 

 

Add multiple types of user input to host 
board or project 

 

Additional static slide switch 

 

Small PCB size for flexible designs 1.5 in × 
0.8 in (3.8 cm × 2.0 cm) 

 

6-pin Pmod connector with GPIO interface 

 

Follows Digilent Pmod Interface 
Specification Type 1 

 

Library and example code available 
in

 

resource center

 

 

Features include: 

Отзывы: