Plug-in Automation Controls
The Plug-in Automation controls are used to enable parame-
ters for automation and to place them in automation safe
mode.
Enable Parameters Switch
The Enable Parameters switch lets you enable parameters for
automation by touching or pressing their controls.
In Enable Parameters mode, the Enable Parameters switch is
lit. While in this mode, the Auto LED for any rotary encoder
enabled for automation is lit red, and the switch for any pa-
rameter enabled for automation is lit.
To toggle automation on and off for plug-in parameters:
1
Press the Enable Parameter switch.
2
Touch the rotary encoders or press the switches for the con-
trols for which you want to toggle automation on or off.
3
Press the Enable Parameter switch again to exit Enable Pa-
rameters mode.
Automation Safe Switch
The Automation Safe switch invokes a mode in which the By-
pass/Mute/Pre switch for each plug-in or send and the chan-
nel Select switch for each track become Safe switches.
Plug-ins and Sends
While in Automation Safe mode, pressing a Bypass/Mute/Pre
switch on a plug-in or send protects any automation on that
plug-in or send from being overwritten. The Bypass/Mute/Pre
switch for any protected plug-in or send is lit, reflecting the
state of the Safe button in the on-screen plug-in or send out-
put window.
Tracks
While in Automation Safe mode, pressing a channel Select
switch protects volume, pan and mute parameters on that
track from being overwritten. The channel Select switch for
any protected track is lit, reflecting the state of the Safe button
in the on-screen track output window.
To toggle automation safe on and off:
1
Press the Automation Safe switch.
2
Press the channel Select switch on the tracks for which you
want to toggle automation safe status. The automation safe
status of the track is reflected by the Safe button in the track’s
on-screen output window.
3
Press the Bypass/Mute/Pre switch for the plug-ins or sends
for which you want to toggle automation safe status.
4
Press the Automation Safe switch again to exit Automation
Safe mode.
Plug-in Automation controls
You can also toggle automation for a plug-in parameter by
holding Start+Alt (Windows) or Con-
trol+Option (Mac) and touching the rotary encoder for the
parameter.
Enable Parameter
switch
Automation Safe
switch
Содержание D-Command
Страница 1: ...D Command Version 7 3 ...
Страница 4: ......
Страница 7: ...Part I Introduction ...
Страница 8: ......
Страница 12: ...D Command Guide 6 D Command top dimensions Main Unit and Fader Module 55 6 in 141 2 cm 29 25 in 74 3 cm ...
Страница 19: ...Part II Installation ...
Страница 20: ......
Страница 35: ...Part III Reference ...
Страница 36: ......
Страница 72: ...D Command Guide 66 ...
Страница 90: ...D Command Guide 84 ...
Страница 124: ...D Command Guide 118 ...
Страница 128: ...D Command Guide 122 ...
Страница 134: ...D Command Guide 128 ...
Страница 135: ......