background image

18

6.6 Power supply

This power supply was especially designed for the CATRAX

. Among the main

line

advantages of this optional item, is its adaptation capability to the voltage variations
often found in installation sites – the input voltage can vary between 100 and 240
Vca.
The supply's specific technical features, protections and dimensions were carefully
tested and approved in hostile temperature and environmental conditions, which
ensures the adequate power supply to the equipment's performance. Besides the
input and output voltages indicated in the image below, the supply has a short-circuit
and overheating protection.

6.7 Control board

CATRAX Master

control board was designed to meet most technologies of access

control terminals in the market. The controller have mechanical features and layout
perfectly suited for the

needs and it is one of the best options for

CATRAX Master

the equipment's operation.
The following images show the control board with its straps, connectors, and
dipswitch, as well as the location of the power supply and the control board in

CATRAX Master

.

The table below describes the functions of the control board's connectors:

TIP

:

The power supply can be mounted to the board's support that

accompanies

.

CATRAX Master

Cn1

Cn2

Ds1

Cn8

ENTRADA:

100 A 240 Vca

SAÍDA:

Terra

Neutro

Fase

12V     5% / 3A

+-

GND

master

Содержание catrax master

Страница 1: ...1 Product Manual master...

Страница 2: ...2...

Страница 3: ...lated into any language or computer language in any electronic magnetic optical chemical manual way or otherwise without the express written permission from Digicon S A Code 069 31 251 English Version...

Страница 4: ...s 6 7 2 Outputs 6 7 2 1 Return signals 6 5 2 2 Electromagnets 6 7 2 3 Sound alarm 6 7 2 4 Connection scheme 6 7 2 5 Pictogram 6 7 2 6 Pictrogram connections 6 7 3 Configuration od control board Switch...

Страница 5: ...omething Digicon considers important CAUTION Indicates a moment of extreme caution when handling the equipment product ATTENTION Indicates a moment when your observation skills should be extremely pro...

Страница 6: ...in this manual and cannot be held responsible for errors it may contain and problems due to its use The information contained in this manual is exclusive property of Digicon and is protected by copyri...

Страница 7: ...rds Moreover the clients according to their needs can add additional holes Access to the mounting rack is done through a key with secret whose removal and insertion are extremely easy A plastic cover...

Страница 8: ...quipment will allow the turning of the arm of After half of the turning is complete 60 degrees a 400 CATRAX Master milliseconds returning signal will be sent informing the passage direction After the...

Страница 9: ...all Digicon packages ATTENTION To avoid losses the screws and the wrenches used for assembling the are attached to the box containing the CATRAX Master arms Before discarding the packing materials ca...

Страница 10: ...ensions see item 8 Technical characteristics 6 If the floor is in conditions to receive anchor bolts minimum of 4 cm of FCK15 M P A concrete or equivalent Once you observe these recommendations procee...

Страница 11: ...lling the floor and installing the column it is possible to assemble the arms as shown below INFORMATION The cover to access the screws is open closed by pressure fitting To assemble the arms use an A...

Страница 12: ...s for opening CATRAX Master after assembly 1 Unlock the two extremities of the using the key provided CATRAX Master alongside the product Remove the external covers which are pressed into place The co...

Страница 13: ...ipment structure contains a device that maintains the cover in the vertical position see detail 4 The following image shows with all covers open CATRAX Master INFORMATION To access the column door rem...

Страница 14: ...AX Master the columns The sheet can be of 6 mm tempered glass 6 mm acrylic or and 1 2 mm stainless steel as the client sees fit Besides closing the rear space the panel allows simple customization wit...

Страница 15: ...cards is part of the kit and is positioned under the collecting kit The badge reader is not part of the kit ATTENTION The power supply has no ground wire connection Grounding is done directly in the...

Страница 16: ...tronic counter offers inputs for two sensors allowing it to be configured for sequential sensing making it possible to detect turnstile rotations in a given direction The device is also capable of cou...

Страница 17: ...s to distinguish the two tuning directions To configure the counter it is necessary to access the total visualization mode and proceed as shown Sensors The sensors must connect the sensor s input to t...

Страница 18: ...w the supply has a short circuit and overheating protection 6 7 Control board CATRAX Master control board was designed to meet most technologies of access control terminals in the market The controlle...

Страница 19: ...12Vcc indicative arrows power red wire 9 GND indicative arrows power black wire 10 solenoid of badge collector box 11 solenoid of badge collector box 12 Sound signal open collector NPN CN3 SERIAL RS 4...

Страница 20: ...ted on each side of the equipment X X PIC1 pino 15 PIC2 pino 16 Pictogram 1 Pictogram 2 Open Open GND GND Open GND Open GND X X Particularly about the CN11 connector pins 13 and 14 can be CATRAX Maste...

Страница 21: ...normally open contact NO or normally closed contact NC Connect the outputs according to the image below 6 7 2 2 Electromagnets Electromagnets are activated for blocking the turnstile Opposite to the t...

Страница 22: ...aximum 500 mA at the moment of activation the GND is sent through a corresponding output 6 7 2 6 Pictogram connections master Sound alarm Maximum current 500mA Inputs Inputs Relay Outputs Acess contro...

Страница 23: ...l OFF Enables sound signal in mid turn ON Disables sound signal in mid turn OFF Wait until first turn ON ON Wait for 5 seconds OFF ON Wait for 10 seconds ON OFF Wait for 15 seconds OFF OFF Habilitatio...

Страница 24: ...STX Size LSB Size MSB Commands BCC HEXA ASCII FUNCTION 0x48 H Clears direction from right to left 0x41 A t Clears direction from left to right 0x44 D Clears both directions 0x43 C Back to controlling...

Страница 25: ...rm raised during normal operation In case of power outage when the installation has no no break or through a command sent via system or the activation of an emergency button in the control room the el...

Страница 26: ...e solenoid the control board has an automatic routine that reduces its voltage to 6Vcc two seconds after the turnstile is turned on One disassembled the arm should be placed manually back into positio...

Страница 27: ...crew must be tightened to the maximum to ensure good fixation All three arms must be attached to the same central upper point master 2 Make sure the mini arm s plastic part is fitted in to the steel p...

Страница 28: ...e If the mechanism presents any defect request maintenance to a Digicon technician or a qualified company Each inspection should carry out the following operational sequence for each of the three arm...

Страница 29: ...8Vcc non obstructed sensors With the pointers at the same position force the equipment s arms to both directions in one of the sides the voltage should be higher than 4 5Vcc Repeat the same operation...

Страница 30: ...ctions you must check the lock s correct position check the wear of the lock s fitting in the sprocket Corrective actions 1 if the lock s position is incorrect check the retaining ring and the spring...

Страница 31: ...d the equipment to the Technical Assistance Request a replacement for the faulty part or forward the equipment to the Technical Assistance Adjust the electromagnet or forward the equipment to the Tech...

Страница 32: ...teristics 8 1 Dimensions 1041 40 984 1041 40 984 1300 51 181 500 19 685 25 0 984 1010 39 763 1116 43 937 972 38 267 657 25 866 425 16 732 INFORMA O The measures presented in this manual are in millime...

Страница 33: ...5 A Power supply optional Input 100 Vca a 240 Vca Output 12 0 Vca 5 3 A Dimensions 35 x 51 x 105 mm Distance between holes 43 x 98 mm Diameter of holes 3 5 mm Board with display Power 6 a 24 Vcc 100 m...

Страница 34: ...lvent But be careful never scrape the surface of stainless steel with thick blades spatulas or abrasives Rust spots With a cotton swab dipped in water and nitric acid at 10 make topical applications k...

Страница 35: ...water If this is not enough to soften burned foods or charred deposits use more aggressive products such as caustic soda removers used in household cleaning TIP Even in the case of stubborn dirt try...

Страница 36: ...technical assistance 3 Warranty shall be granted to the buyer only in the face of the bill of sale original or copy 4 Warranty does not apply in the following cases or conditions a defects and damage...

Страница 37: ...37...

Страница 38: ...Castiel 640 Distrito Industrial Gravata 94045 RS CEP 420 Sales 0xx51 3489 8700 3489 8745 Technical assistance 0xx51 3489 8903 Email vendas acesso digicon com br Branch office SP Street S o Paulo 82 A...

Отзывы: