![Digi XGI-20CZ7-E00-W0 Скачать руководство пользователя страница 132](http://html1.mh-extra.com/html/digi/xgi-20cz7-e00-w0/xgi-20cz7-e00-w0_user-manual_2496341132.webp)
Learn more about XBee Industrial Gateway
Connect the XBee nodes to XBee Industrial Gateway
Digi XBee Industrial Gateway
132
6. If XBee Industrial Gateway uses XBee security parameters, set the XBee security parameters
(
EE
,
EO
,
NK
,
KY
) as needed. The security parameters are as follows:
n
EE
: Enable or disable security in the network.
n
EO
: Set the security policy for the network.
n
NK
: Set the network security key for the network. If set to 0 (default), the device will
use a random network security key.
n
KY
: Set the trust center link key for the network. If set to 0 (default), the device will use
a random network security key.
For more information on these parameters, see the
XBee/XBee-PRO S2C ZigBee RF Modules User
7. Click the
Write radio settings
button to save the new security settings in the XBee module. As
soon as you save the new PAN ID in the XBee RF module, the module tries to connect to the
ZigBee network that has the PAN ID that you configured.
Verify that XBee nodes are joined to the coordinator
To verify that your XBee ZigBee module has successfully joined the ZigBee network:
1. Make sure XBee Industrial Gateway is powered on. Make sure the XBee ZigBee node is
mounted on the development board and that the development board is powered on.
2. From a web browser, open the
Home
page of your XBee Industrial Gateway.
3. Under
Configuration
, click
XBee Network
. The XBee Configuration page appears.
4. Below the Remote XBee Devices table, select the
Clear list before discovery
check box and
click the
Discover XBee Devices
button.
5. After some seconds the
Remote XBee Devices
table displays your XBee ZigBee node.
Содержание XGI-20CZ7-E00-W0
Страница 1: ...Digi XBee Industrial Gateway User Guide...