AT commands
Serial interfacing commands
XBee/XBee-PRO DigiMesh 2.4 RF Module User Guide
85
Parameter
Description
0
Disabled
1
Enabled
Default
0
KY (AES Encryption Key)
Sets the 16-byte network security key value that the device uses for encryption and decryption.
This command is write-only. If you attempt to read
KY
, the device returns an
OK
status.
Set this command parameter the same on all devices in a network.
Parameter range
128-bit value
Default
N/A
Serial interfacing commands
The following AT commands are serial interfacing commands.
BD (Baud Rate)
Sets or displays the serial interface baud rate for communication between the device's serial port and
the host.
To request non-standard baud rates with values above 0x80, you can use the Serial Console toolbar in
XCTU to configure the serial connection (if the console is connected), or click the
Connect
button (if
the console is not yet connected).
When you send non-standard baud rates to a device, it stores the closest interface data rate
represented by the number in the
BD
register. Read the
BD
command by sending
ATBD
without a
parameter value, and the device returns the value stored in the
BD
register.
Parameter range
Standard baud rates: 0x0 - 0x7
Non-standard baud rates: 0x39 to 0xF4240 if the host supports it
Value
Description
0x0
1,200 b/s
0x1
2,400 b/s
0x2
4,800 b/s
0x3
9,600 b/s
Содержание XBee DigiMesh 2.4
Страница 1: ...XBee XBee PRO DigiMesh 2 4 Radio Frequency RF Module User Guide...
Страница 63: ...Sleep modes Synchronization messages XBee XBee PRO DigiMesh 2 4 RF Module User Guide 63...
Страница 105: ...Operate in API mode API mode overview 106 API frames 110 XBee XBee PRO DigiMesh 2 4 RF Module User Guide 105...
Страница 112: ...Operate in API mode API frames XBee XBee PRO DigiMesh 2 4 RF Module User Guide 112...