AT commands
Special commands
Digi XBee® 3 Cellular LTE-M/NB-IoT Global Smart Modem User Guide
184
Special commands
The following commands are special commands.
AC (Apply Changes)
Immediately applies new settings without exiting Command mode.
Applying changes means that the device re-initializes based on changes made to its parameter values.
Once changes are applied, the device immediately operates according to the new parameter values.
This behavior is in contrast to issuing the
WR
(Write) command. The
WR
command saves parameter
values to non-volatile memory, but the device still operates according to previously saved values until
the device is rebooted or you issue the
CN
(Exit AT Command Mode) or
AC
commands.
Parameter range
N/A
Default
N/A
FR (Force Reset)
Resets the device. The device responds immediately with an
OK
and performs a reset 100 ms later.
If you issue
FR
while the device is in Command Mode, the reset effectively exits Command mode.
Note
Digi recommends shutting down the cellular component before resetting or rebooting the device
to allow the cellular module to detach from the network. The cellular component can be shut down by
issuing the
.
Parameter range
N/A
Default
N/A
RE (Restore Defaults)
Restore device parameters to factory defaults.
The
RE
command does not write restored values to non-volatile (persistent) memory. Issue the
WR
(Write) command after issuing the
RE
command to save restored parameter values to non-volatile
memory.
Parameter range
N/A
Default
N/A