Extended Socket frames
Extended Socket example: TCP Listener
Digi XBee® 3 Cellular LTE-M/NB-IoT Global Smart Modem User Guide
174
Field
Value
Frame type
(Socket Listen)
Frame ID
0x01
Socket ID
0x00
Source Port
0x2711 (10001)
Socket Bind/Listen frame data:
7E 00 05 46 01 00 27 11 80
Receive a Socket Bind/Listen Response
The Socket Bind/Listen Response contains a Status. A Status of zero is a success and any other value
is an error.
Field
Value
Frame type
(Socket Listen)
Frame ID
0x01
Socket ID
0x00
Status
0x00 (Success)
Socket Bind/Listen frame received from XBee:
7E 00 04 C6 01 00 00 38
Making a connection to the listener socket
The IP of the XBee can be acquired through the MY at command.
ATMY
172.20.1.235
Using an external tool like netcat, a connection can be made to the given address.
nc -p 10001 172.20.1.235 10001
Hello XBee!
After the connection has been made, the XBee outputs a Socket New IPv4 Client frame indicating the
presence of a new client connection. It contains the listener's socket ID and the new Client Socket ID
along with the connection's remote address information.
Field
Value
Frame type
(Socket New IPv4 Client)