![Digi S6B Скачать руководство пользователя страница 179](http://html.mh-extra.com/html/digi/s6b/s6b_user-manual_2496668179.webp)
AT commands
Sleep commands
XBee Wi-Fi RF Module User Guide
179
Bit
Option
0x100 For cyclic sleep,
ST
specifies the time before returning to sleep. With this bit set, new
receptions from either the serial or the RF port
do not
restart the
ST
timer. Current
implementation does not support this bit being turned off.
Parameter range
0 - 0x01FF
Default
0x100
WH (Wake Host)
Sets or reads the wake host timer value.
If you set
WH
to a non-zero value, this timer specifies a time in milliseconds that the device delays
after waking from sleep before sending data out the UART or transmitting an I/O sample. If the device
receives serial characters, the
WH
timer stops immediately.
Parameter range
0 - 0xFFFF (x 1 ms)
Default
0
ST (Wake Time)
Sets or reads the time to spend awake in cyclic sleep modes.
If there is data to transmit or receive after
ST
expires, those actions occur before the module goes to
sleep. Max wake time is 3600 seconds.
Parameter range
0x1 - 0x36EE80 (x 1 ms)
Default
0x7D0 (3 seconds)
SA (Association Timeout)
Time to wait for association before entering deep sleep. Wakeup from deep sleep is much faster if
association occurs before going to sleep.
Parameter range
0x1 – 0x36EE80 (x1 ms)
Default
0x2710 (10 seconds)