Rapidport Installation Guide (90000665 Rev. C) – Page 6 

Remap Baud

: (All operating systems - 930 and TI based Edgeport) 

Setting the baud rate to 1200 baud will result in 230400 baud 

Ignore Flush

: (Windows NT/2K/XP 930 and TI) 

If an application sends IRP_MJ_FLUSH_BUFFERS it will be ignored. 

Excerpt from Microsoft documentation:  

Drivers of devices with internal caches for data and drivers that maintain internal buffers for data must 
handle this request. 

When Sent 

Receipt of a flush request indicates that the driver should flush the device's cache or its internal buffer, or, 
possibly, should discard the data in its internal buffer. 

Operation 

The driver transfers any data currently cached in the device or held in the driver's internal buffer(s) before 
completing the flush request. The driver of an input-only device that buffers data internally might simply 
discard the currently buffered device data before completing the flush IRP, depending on the nature of its 
device. 

Fast Writes

: (All operating systems - 930 and TI based Edgeport) 

When an application sends a write to the driver, by default the Edgeport driver will wait until all data has 
been transmitted out of the Edgeport device before completing the write. When the Fast Writes flag is set, 
we complete the write even if data is still buffered in the driver and the Edgeport device. 

Fast Reads

This flag is used when an application requires that a read complete immediately. In the read immediate 
case, the Edgeport driver will send a request to the Edgeport device asking for any buffered data to be sent 
up.  This buffered data will be included when the read completes.  If this flag is set, the driver will not 
query the Edgeport device for additional data. 

Disable Plug & Play

: (Windows 2k/XP only) 

Do not let the serial port enumerator detect devices plugged into the Edgeport. 

Ignore Tx Purge: 

The IOCTL_SERIAL_PURGE request cancels the specified requests and deletes data from the specified 
buffers. The purge request can be used to cancel all read requests and write requests and to delete all data 
from the read buffer and the write buffer. 

When the 

Ignore Tx Purge

 flag is set the SERIAL_PURGE_TXCLEAR command will be ignored. The 

function will not purge the write buffer. 

Timer Logic

: (Windows 9x only) 

If application uses PortSetReadCallBack(), the notification routine will only be called when the number of 
bytes in the receive buffer is greater then the RX trigger.  The Microsoft serial VxD also implements a 
timer that will trigger and call the notification routine if some amount of data is available in the RX buffer 
but no new data has been received for ~200ms (receiver is no longer active).   

We do not enable this behavior by default because of the nature of Edgeport buffering. But if you set the 
flag we will complete the read when we detect ~200 ms no activity. 

Here is a comment from the code: 

If the receiver is active then do not complete this read. The problem is that the Edgeport buffers the RX 
bytes and we poll the driver.  If we do not receive any bytes in 200ms we may report an erroneous event 
even if there are available bytes in the Edgeport device or driver. 

Содержание Rapidport

Страница 1: ...Rapidport USB TO 4 PORT MODEM MODULE Installation Guide www digi com...

Страница 2: ...Table of Contents Cabling Rapidport 1 Installing Rapidport Drivers 2 Installing the Rapidport Modems 3 Interpreting the Status Lights 3 The Edgeport Utility Program 4 Regulatory Other Information 10...

Страница 3: ...elecommunication line cord 3a For a downstream connection plug the Type A end of the USB cable into the USB port located in the back of your PC or into an available USB port on a standard hub or into...

Страница 4: ...driver update server If not continue with step 3 2 Insert the Edgeport Driver CD into your CD ROM drive In most cases the drivers will be automatically installed from the CD If not proceed with step...

Страница 5: ...ndicates a problem with the drivers which may need to be reinstalled The red light will also blink during installation until the installation is complete Amber This light signifies serial port activit...

Страница 6: ...s you to manage the serial ports of your Rapidport product Note that with Windows NT you must have administrative privileges in order to change the COM port settings For more information see the Suppo...

Страница 7: ...lags Configure performance options and special functionality on a per port basis Low Latency 930 based Edgeport only Normally the UART will interrupt when the receiver has been idle for 4 character ti...

Страница 8: ...ort driver will send a request to the Edgeport device asking for any buffered data to be sent up This buffered data will be included when the read completes If this flag is set the driver will not que...

Страница 9: ...rt Installation Guide 90000665 Rev C Page 7 Test Ports Perform a confidence test on the internal workings of the serial ports Power Management Turn on and off the power for Hubports with USB PlusPower...

Страница 10: ...on and enter a filename for the log file This file will contain all of the information displayed in the Port Status window until the Stop Logging button is clicked Refresh Scan for ports Note that NT...

Страница 11: ...e driver identifies a converter based on the physical USB port it is plugged into This effectively assigns COM port numbers to physical USB ports No matter which converter is plugged into a given USB...

Страница 12: ...ed unless otherwise provided for in the license agreement Federal Communications Commission FCC Regulatory Information USA only This equipment has been tested and found to comply with the limits for a...

Страница 13: ...2 Class B emission and immunity tests and the EN61000 3 2 2000 EN61000 3 3 1995 current harmonics and voltage variation tests Actual test levels are listed in the appropriate tables EN 55022 Class B 1...

Страница 14: ...12 Digi International 11001 Bren Road East Minnetonka MN 55343 digi info digi com www digi com Corporate Headquarters 952 912 3444 877 912 3444 Fax 952 912 4952 Digi Europe 49 231 9747 0 Digi Hong Ko...

Отзывы: