Page 30
Installation
90030500B
Recommended maximum distance limitations
The maximum recommended length of each type of cable connection you may use
with PortServer II are shown below.
Note:
Although PortServer II may operate adequately if you exceed a given limita-
tion, performance may be degraded.
Ethernet
10BaseT: Maximum distance of 330 ft (100 M) at a transmission rate of 10
megabits/second (10 Mbps).
10Base2: Maximum distance of 610 ft (185 M) at a transmission rate of 10
megabits/second (10 Mbps).
EIA RS-232 serial ports
Maximum distance depends on the data rate and the type of cable:
V.24 cable
If you are connecting to a Frame Relay service, you require a fully V.24-compatible
cable. Distance limitations are the same as for serial cables.
Table 1
RS232 Serial Port Specifications
Data Rate (Baud)
Distance (ft)
Distance (M)
2400
200
60
4800
100
30
9600
50
15
19200
25
7.5
38400
12.5
3.8
57600
6.3
1.9
115200
3.2
0.9
Содержание PortServer II
Страница 1: ...8VHU V XLGH PortServer II QWHOOLJHQW 1HWZRUN RPPXQLFDWLRQV DQG 7HUPLQDO 6HUYHU ...
Страница 2: ......
Страница 4: ...90030500B Page ii ...
Страница 20: ...Page xviii About this User s Guide 90030500B ...
Страница 74: ...Page 54 Installation 90030500B ...
Страница 106: ...Page 86 Configuring Terminals 90030500B ...
Страница 144: ...Page 124 Configuring WAN Connections 90030500B ...
Страница 168: ...Page 148 Configuring TCP IP Routing 90030500B ...
Страница 180: ...Page 160 Configuring SNMP 90030500B ...
Страница 206: ...Page 186 Remote Configuration 90030500B ...
Страница 264: ...Page 244 Digi Support Services 90030500B ...
Страница 270: ...Page 250 Glossary 90030500B ...