Virtual Private Networks (VPN)
IPsec
IX10 User Guide
295
1. Select the device in Remote Manager and click
Actions
>
Open Console
, or log into the IX10
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
admin
to access the Admin CLI.
2. At the command line, type
config
to enter configuration mode:
> config
(config)>
3. Set the IPsec debug value:
config> vpn ipsec advanced debug
value
config>
where
value
is one of:
n
none
. (Default) No debug messages are written.
n
basic_auditing
: Logs basic auditing information, (for example, SA up/SA down).
n
generic_control
: Select this for basic debugging information.
n
detailed_control
: More detailed debugging control flow.
n
raw_data
: Includes raw data dumps in hexadecimal format.
n
sensitive_data
: Also includes sensitive material in dumps (for example, encryption
keys).
4. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
5. Type
exit
to exit the Admin CLI.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
quit
to disconnect from the device.
Configure a Simple Certificate Enrollment Protocol client
Simple Certificate Enrollment Protocol (SCEP) is a mechanism that allows for large-scale X.509
certificate deployment. You can configure IX10 device to function as a SCEP client that will connect to
a SCEP server that is used to sign Certificate Signing Requests (CSRs), provide Certificate Revocation
Lists (CRLs), and distribute valid certificates from a Certificate Authority (CA).
Required configuration
n
Enable the SCEP client.
n
The fully-qualified domain name of the SCEP server to be used for certificate requests.
n
The challenge password provided by the SCEP server that the SCEP client will use when
making SCEP requests.
n
The distinguished name to be used for the CSR.
Содержание IX10
Страница 1: ...IX10 User Guide User Guide Firmware version 22 5 ...
Страница 444: ...Services Simple Network Management Protocol SNMP IX10 User Guide 444 The SNMP page is displayed 4 Click Download ...
Страница 740: ...Monitoring This chapter contains the following topics intelliFlow 741 Configure NetFlow Probe 748 IX10 User Guide 740 ...
Страница 823: ...Command line interface Execute a command from the web interface IX10 User Guide 823 The Admin CLI prompt appears ...
Страница 849: ...Command line interface Command line reference IX10 User Guide 849 Parameters None ...
Страница 858: ...Command line interface Command line reference IX10 User Guide 858 reboot Reboot the system Parameters None ...