Digi DI-28SS Скачать руководство пользователя страница 1

 

Page 

1

 of 

6

 

 

User Guide 

 
 

 

DI-28SS 

WEIGHING INDICATOR 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

Teraoka Seiko Co., Ltd. 

<

  Head office > 

13-12 Kugahara 5-chome, Ohta-Ku, Tokyo 146-8580 Japan TEL: +81-3-3752-
2131,FAX: +81-3-3752-2801 

<

  Ohsaki office > 

2-3-13 Ohsaki, Shinagawa-Ku, Tokyo 141-8566 Japan TEL: +81-3-5496-7600,FAX: 
+81-3-5496-7620 

http://www.digisystem.com

 email:

[email protected]

 

 

Содержание DI-28SS

Страница 1: ...iko Co Ltd Head office 13 12 Kugahara 5 chome Ohta Ku Tokyo 146 8580 Japan TEL 81 3 3752 2131 FAX 81 3 3752 2801 Ohsaki office 2 3 13 Ohsaki Shinagawa Ku Tokyo 141 8566 Japan TEL 81 3 5496 7600 FAX 81 3 5496 7620 http www digisystem com email info hq digi co jp ...

Страница 2: ...Page 2 of 6 Contents Overview 2 Features 2 Description of display 4 Key switch function 4 Function setting 5 Error messages 6 Operation mode 6 ...

Страница 3: ... 20 times second 3 Internal resolution 1 300 000 4 Display resolution 1 1000 1 30 000 division 5 Non linearity 0 016 F S 6 Rated Output 0 20mV 7 Excitation Voltage _DC5V Analog up to 4 x 350Ω load cell 8 Power supply DC6V 4Ah re charge battery or AC230V power supply 9 Display 6 digits LED display and height 25mm LED 10 LED indicate G W N W tare zero ct oz lb kg 11 Power consumption 1W 12 Operating...

Страница 4: ...t The weight is over the preset value OK Pass limit The weight I between HI LO preset value LQ Low limit The weight is under the preset value Switch bottom function 1 Switches Power On Off i Press I once the display show a self test and come to Zero on the screen Each LED will display 0 to 9 in sequence during the self test ii Press and hold I for 3 0 second the display will shut down automaticall...

Страница 5: ... Press to choose On or OFF for buzzer sound or not sound 3 Press M the display show L XX X Press to select a new value for weight under the limit LO 4 Press M the display show 0 XX X Press to select a new value for weight between the HI LO limit OK 5 Press M the display show H XX X Press to select a new value for weight over the limit HI 6 Press M the display show 08 09 10 Mean is year month day 0...

Страница 6: ... stable To check the flatform structure To open the platform structure and clean the structure The scale can not do calibration To check the calibration jumper put to ON position To open casing and palce the cal jumper ON position The scale is not accurate The Loadcell is not good in condition To replace the new Loadcell Operation Mode Open the casing switch the jumper JP1 to OFF position The func...

Отзывы: