Configure the device using the Digi ConnectPort X Family web interface
Administration
Digi ConnectPort X Family
200
For ConnectPort X4 H, the Reset button is located inside the NEMA enclosure on the printed
circuit board, and is named SW1. The figure shows the location of SW1.
3. Hold the
Reset
button down gently with a non-conductive, small diameter tool (such as wood
or plastic) with a blunt end (NOT SHARP or the button could be damaged). Power on the device
while holding the Reset button down. On some models, after a few seconds you may see the
Status LED blink a 1-1-1 pattern once.
4. After 30 seconds, release the Reset button. At this point, on some models, the Status LED will
blink a 1-5-1 pattern. Wait for the device to boot up. At this time, the configuration is returned
to factory defaults. Now, if desired, power off the device, though this is not necessary.
Note
Powering off the device
before
releasing the Reset button guarantees the configuration
will NOT be reverted. Powering off the device
just after
releasing the Reset button will result in
an unknown configuration, possibly having some or all settings reverted to defaults.
System information
The System Information page displays general system information about the Digi ConnectPort X
Family device. Technical support uses this information to troubleshoot problems. To display these