Configure the device using the ConnectPort LTS web interface
Configuration through the web interface
Digi ConnectPort LTS User Guide
79
n
Send alarms based on serial data pattern matching:
Click this radio button to specify that
this alarm is sent when the specified serial data pattern is detected. Then specify the following:
l
Serial Port:
The serial port to monitor for the data pattern. This field appears for devices
where more than one serial port is available.
l
Pattern:
When the serial port receives this data pattern it sends an alarm. You can include
special characters such as carriage return carriage return (\r) and new line (\n) in the data
pattern.
Alarm Destinations
Use the Alarm Destinations page to define how alarm notifications are sent, either as an email
message or an SNMP trap, or both, and where the alarm notification is sent.
n
Alarm Type
: Specify the alarm type to send. Your options are as follows:
[
none
|
|
snmptrap
|
all
]
n
Alarm Description
: The text to include in the Subject: lien of the alarm-notification email or
SNMP traps description.
n
Send SNMP trap to the following destination when alarm occurs
: Specifies whether to
send the alarm as an SNMP trap. To send alarms as SNMP traps, you must set the
Alarm Type
to
snmptrap
and specify the IP address of the destination for the SNMP traps in the SNMP
settings.
To configure an alarm notification to be sent as both an email message and an SNMP trap:
1. Select both
Send E-Mail
and
Send SNMP trap
check boxes.
2. Click
Apply
to apply changes to alarm settings and return to the Alarms Configuration page.
Configure alarm conditions
To configure an alarm:
1. Select
Configuration
>
Alarms
.
2. To enable or disable an alarm, select or clear the Enable check box next to the alarm.
3. Click the alarm under the
Alarm
column that you want to configure.
4. Configure the fields in the following sections:
n
Alarm Conditions
: These condition specify the conditions on which the alarm is based,
such as serial data pattern matching or data usage.
n
Alarm Destinations
: These conditions specify how the alarm is sent, either as an email
message or an SNMP trap, or both, and where the alarm is sent.
5. Click
Apply
to save your changes.
System Configuration
Use the System Configuration page to configure device identity and description information, date and
time settings, and settings for Simple Network Management Protocol (SNMP).