background image

CMi4160 

– LoRaWAN

®

 Module 

 

3  

02/2021 

1

 

DOCUMENTS NOTES 

All information in this user guide, including product data, diagrams, charts, etc. represents information 
on products at the time of publication, and is subject to change without prior notice due to product 
improvements or other reasons. It is recommended that customers contact Diehl Metering GmbH for 

the latest product information before purchasing a CMi Series product.

 

 

The documentation and product are provided on an “as is” basis only and may contain deficiencies or 
inadequacies. Diehl Metering GmbH takes no responsibility for damages, liabilities or other losses by 
using this product. 

 

1.1

 

COPYRIGHT AND TRADEMARK 

© 2020, Diehl Metering GmbH. All rights reserved. No part of the contents of this user guide may be 
transmitted or reproduced in any form by any means without the written permission of Diehl Metering 
GmbH.  

 

2

 

IMPORTANT USAGE AND SAFETY INFORMATION 

The following safety precautions must be observed during all phases of the operation, usage, service 
or repair of any CMi Series product. Users of the product are advised to convey the information to 

users and operating personnel and to incorporate these guidelines into all user guides supplied with 
the product. Failure to comply with these precautions violates safety standards of design, manufacture 

and intended use of the product. Diehl Metering GmbH assumes no liability for customer’s failure to 
comply with these precautions. 

 

CMi4160  receives  and  transmits  radio  frequency  energy  while  switched  on.  Remember  that 
interference  can  occur  if  the  product  is  used  close  to  TV  sets,  radios,  computers  or  inadequately 

shielded  equipment.  Follow  any  special  regulations  and  always  switch  off  the  product  wherever 
forbidden, or when you suspect that it may cause interference or danger. 

3

 

USING THIS USER GUIDE 

3.1

 

PURPOSE AND AUDIENCE 

This user guide provides all information needed to mount, deploy and configure CMi4160 and targets 
installers and system integrators.  
 

3.2

 

SYMBOLS 

The following symbols are used throughout the user guide to emphasize important information and 
useful tips: 

 

The  Note  symbol  is  used  to  mark  information  that  is  important  to  take  into 

consideration  for  safety  reasons  or  to  assure  correct  operation  of  the  meter 
connectivity module. 

 

 

The Tip symbol is used to mark information intended to help you get the most out of 

your product. It can for example be used to highlight a possible customization option 
related to the current section.  

 
 

 

 

Содержание LoRaWAN CMi4160

Страница 1: ...CMi4160 LoRaWAN Module For Diehl Metering SHARKY 775 User guide...

Страница 2: ...ection of battery pack 5 5 3 3 Connection of antenna 5 5 3 4 Network preparation 6 5 3 5 Activation 6 5 3 6 Switch off reboot module 7 6 Administration reference 7 6 1 Purpose 7 6 2 Security and acces...

Страница 3: ...nnel and to incorporate these guidelines into all user guides supplied with the product Failure to comply with these precautions violates safety standards of design manufacture and intended use of the...

Страница 4: ...ttery lifetime The module s EcoMode feature enables the module to achieve a battery lifetime of at least 11 1 years No meter installation needed As soon as the meter connectivity module has been mount...

Страница 5: ...r interface ribbon cable 3 5 3 2 CONNECTION OF BATTERY PACK The CMi4160 is delivered with a battery pack Connect the battery pack to the module s power connector 4 and gently place it with in the mete...

Страница 6: ...etwork join field in the Inspect tab of the OTC App Network join When activated CMi4160 will attempt to join the LoRaWAN network The phase is indicated by short flash on red light then green and red L...

Страница 7: ...f CMi4160 6 2 SECURITY AND ACCESS CONTROL CMi4160 has a configuration lock feature which prevents unauthorized access to the module When configuration lock has been enabled a Product Access Key will b...

Страница 8: ...attery life is guaranteed by adapting the transmit interval of the module to current signal conditions On Readable Writeable Readable Writeable Transmit interval Sets the number of minutes between eac...

Страница 9: ...e meter is assumed to be in standard local time no DST When synchronizing time in the meter using the OTC App local standard time is always used even if DST is in effect The timestamped meter data sen...

Страница 10: ...oMode table If a lower transmit interval is needed for the specific data rate in order to achieve 11 years of battery life the module will adjust the parameter accordingly Table 3 shows the transmit i...

Страница 11: ...s presented Standard Figure 5 illustrates the structure of message format Standard For a detailed description of the payload see Table 5 Figure 5 Structure message format Standard DIB Field Size Data...

Страница 12: ...m3 h 023Fxxxx xxxx 10 m3 h 5 Fw temp 4 bytes INT16 Forward temperature C 0258xxxx xxxx 0 001 C 0259xxxx xxxx 0 01 C 025Axxxx xxxx 0 1 C 025Bxxxx xxxx C 6 Rt temp 4 bytes INT16 Return temperature C 025...

Страница 13: ...address 10 bytes According to M Bus EN13757 3 identification field Meter address Byte 0 1 DIF VIF code Byte 2 5 Meter ID BCD8 lsByte msByte Byte 6 7 Meter manufacturer lsByte msByte Byte 8 Meter vers...

Страница 14: ...day and the data message at least regulated by transmit interval parameter or EcoMode once every day The transmit interval can only be set the values listed in Table 10 Note that although the meter r...

Страница 15: ...INT32 Volume m3 0413xxxxxxxx xxxxxxxx 0 001 m3 0414xxxxxxxx xxxxxxxx 0 01 m3 0415xxxxxxxx xxxxxxxx 0 1 m3 0416xxxxxxxx xxxxxxxx m3 0417xxxxxxxx xxxxxxxx 10 m3 3 Meter address 10 bytes According to M...

Страница 16: ...te to indicate that the value is not valid Table 11 Payload message format Scheduled daily redundant Scheduled Extended The data message of Scheduled mode Extended contains all the data fields from me...

Страница 17: ...flags 13 bytes INT72 Byte 0 3 DIF VIF codes 0x0DFF21E9 Byte 4 Error flags Byte 5 8 Meter ID BCD8 lsByte msByte Byte 9 10 Meter manufacturer lsByte msByte Byte 11 Meter version Byte 12 Device type 5 M...

Страница 18: ...040Fxxxxxxxx xxxxxxxx 10 MJ 04FB0Dxxxxxxxx xxxxxxxx MCal 04FB0Exxxxxxxx xxxxxxxx 10 MCal 04FB0Fxxxxxxxx xxxxxxxx 100 MCal 2 Cooling energy 8 9 bytes INT32 Energy consumption Wh J Cal 0483FF02xxxxxxxx...

Страница 19: ...is unable to communicate with the meter and retrieve meter values in which case all the fields in the payload have the DIF indicating value during error state In case of erroneous data or if the modul...

Страница 20: ...pact 0x20 Message format JSON 0x21 Message format Scheduled daily redundant 0x22 Message format Scheduled Extended 0x23 Message format Combined heat cooling 0x00070101F Sets the message format to comp...

Страница 21: ...erating humidity 0 93 RH No condensation Operating altitude 2 000 m Usage environment Indoors Storage temperature 20 60 C Radio characteristics Operating Frequency Frequency Band 863 1 864 9 K 865 1 8...

Страница 22: ...ion Description DIB Data Information Block DIF Data Information Field VIF Value Information Field MCM Meter Connectivity Module 9 2 NUMBER REPRESENTATION Decimal numbers are represented as normal numb...

Страница 23: ...CMi4160 LoRaWAN Module 23 02 2021...

Страница 24: ...www diehl com metering PfM 02 2021 Specifications subject to change without notice Diehl Metering GmbH Industriestra e 13 91522 Ansbach Phone 49 981 1806 0 Fax 49 9811806 615...

Отзывы: