Getting Started

To setup the VFC320 or VFC325 you’ll need to be at your PC.

Insert Batteries:

  Included in the shipping box are 4AA batteries. Remove the battery door on the 

back  of the unit using a Phillips screwdriver. Insert the 4AA batteries and replace the battery door.  
Position velcro on the back of the unit for mounting.
K-thermoucouple beadwire probe(s) are connected to the unit

Installing DicksonWare™ Software

: Make sure the PC is running Windows 98 or higher 

DicksonWare™ Version 10.0.8 or higher is needed to operate this VaccineData Logger. If you currently 
have DicksonWare™ on the PC, check the version. Choose Help on the Menu Bar. Choose About. The 
version is shown in the dialog box.   

To install and start DicksonWare™ Software

 onto your PC, insert the CD into the CD drive. 

Follow the steps on the screen. Once installed a DicksonWare™ icon appears on the desktop.

Connect

 one end of the USB cable to the logger and the other cable end to the PC. 

Press the 

MIN/MAX

 button to toggle between Fahrenheit and Celsius on the display

Double click the DicksonWare™ icon

. A dialog box appears to register the software. Click on one 

of the options.  

Follow these steps to setup the logger: 

 

a.   Across the top menu bar, choose

 File, Preferences

. Click on Fahrenheit or Celsius for down 

 

 

loaded data temperature readings.  Then choose 

OK

.   

b.   Click the 

Setup

 button located in the upper left hand corner of the software window.  This  

 

 

establishes communication between the Logger and DicksonWare software.   

c.   A dialogue box appears.  Select USB or Serial depending on the type of download cable. 

Click    

 

CONTINUE.

A setup window pops up with five tabs.  The Identification tab is chosen. All fields should be 
automatically filled in. The Model number, Serial number, Calibration Date and Factory Calibration 
Date  are identified. This confirms that DicksonWare has recognized the logger.  
Factory Calibration date identifies when the unit was calibrated. Calibration Date identifies when 
the next calibration is needed.  Should all fields remain blank, refer to “No Communication” in the 
Troubleshooting section of this manual.      
In the setup window, choose the Samples tab.   
a.   No changes can be made to the 

Start Date/Time

, sample interval or stop or wrap when full    

 

section. 

b.  

Samples per Channel

 tells you how many samples of data have been collected and the logger  

 

capacity that has been used. 

c.  

Log Time

 identifies how much time the chosen sample rate will cover to fill the logger.  

d.  

Battery Level

 shows the amount of battery life available. To achieve longer battery life during 

 

operation, use a less frequent sample rate, disconnect the unit from the USB port when not 

 

downloading data, limit the frequency of memory card transfers and DO NOT insert the memory   

 

card all of the way into the logger unless downloading. 

In the setup window, choose the 

Channels

 tab. Each unit has two channels. The temperatures shown   

here are real-time readings. No changes need to be made.

Setup the Min/Max Alarm conditions

  

a.   In the setup window, choose the Ch1 Temp Alarm Tab to set the Min and Max alarm conditions    
 

for Channel 1. Ch1 is the external probe for the VFC320 and top probe for the VFC325. 

b.   In the setup window, choose the Ch2 Temp Alarm Ch2 is the internal sensor for the VFC320 and   
 

the  bottom probe for the VFC325. The factory preset alarm temperature parameters are shown 

 

To change these temperatures, just type in another Minimum temperature and/or Maximum  

 

 

temperature. 

1.

2.
3.

4.

5.

6.

7.

8.

9.

10.

11.

Содержание VFC320

Страница 1: ...Software Specifications Warranty Factory Service Returns Calibrations Product Specifications Accessories Operating Instructions Getting Started Getting Started DicksonWare Software DicksonWare Softwa...

Страница 2: ...H Sensor Type N A N A RH Accuracy N A N A Storage Capacity 32 000 div x 2 32 000 div x 2 Resolution 0 1 0 1 Response Time 63 1 minute 1 minute Accessories for current pricing go to www dicksondata com...

Страница 3: ...installed in the logger will reduce battery life by 50 If you notice Err on the display please refer to the Troubleshooting section of this manual Hardware Display These loggers have a continuous disp...

Страница 4: ...lect USB or Serial depending on the type of download cable Click CONTINUE A setup window pops up with five tabs The Identification tab is chosen All fields should be automatically filled in The Model...

Страница 5: ...creen This feature should be used sparingly as it causes the battery to drain very quickly unless using optional AC adapter Customize Graphed Data DicksonWare calculates Min Max and Average of all dat...

Страница 6: ...is full In Wrap mode the Logger will begin to overwrite the oldest data in its memory 1 2 3 4 5 6 Specifications Compatible With Microsoft Windows 95 98 2000 NT XP PC Requirements PC with 386 MHz or...

Страница 7: ...ge of the power of a PC and software Store the data as you would store any document on your PC Retrieve archived data as easily as opening a file on your PC Share the data as you would any PC file ema...

Страница 8: ...to misuse or neglect Factory Service Returns Contact the factory 630 543 3747 for a Return Authorization RA Number before returning any instrument The model number serial number and a purchase order...

Страница 9: ...mperature Points Documentation of one customer specified point Should be selected in addition to one of the above calibration options Why should I recalibrate my instrumentation Over time dirt dust an...

Страница 10: ...ct Specifications Accessories Operating Instructions Getting Started Getting Started DicksonWare Software DicksonWare Software FAQ FAQ Troubleshooting Warranty Factory Service Returns Calibrations DIC...

Отзывы: