Dickson VFC320 Скачать руководство пользователя страница 5

Rev. 10/07

Pr

od

uc

Sp

ec

ifi

ca

tio

ns 

 

& A
cc

es

so

rie

s

O

pe

ra

tin

In

st

ru

ct

io

ns 

G

et

tin

g S
ta

rt

ed
G

et

tin

g S
ta

rt

ed

D

ic

ks

on

W

ar

e

So

ft

w

ar

e

D

ic

ks

on

W

ar

e

So

ft

w

ar

 

& F
A

Q

FA

Q &

Tr

ou

ble

sh

oo

tin

g

W

ar

ra

nt

y/ 

Fa

ct

or

y S
er

vic

& R
et

ur

ns

C

ali

br

at

io

ns

D

IC

K

SO

N

CAUTION

:  The preset alarm temperatures that you are setting are lower than the ambient or air 

temperature.  Therefore, when the alarm are enabled they will sound. Do the following: 

Silencing the Alarm

 – press the ALARM button on the front of the unit to silence. 

Disabling the Visual Alarm 

– press the ALARM button until CLR will appear on the display. ALRN 

will continue to display until the logger & probe(s) have been positioned in the refrigerator and or 
freezer.

To setup Alarm Features, Click on the Alarms Tab  

a. Check Alarm Enabled to display ALRN across the display if temperatures go out of the desired 
ranges.  
b. Check Buzzer Enabled for an audible alarm if temperatures go out of the desired ranges.  
c. Click on Update to save these changes. To disable these alarms, click on the checkmark and choose   
update. 
d. Alarm Delay: allows delay of alarm notification in minutes up to 60 minutes.  Enter the number of    
minutes and click on update.

Note: These alarm features apply to both channels.
The logger is now sampling and ready for use. A Delta (

) symbol will appear on the display to confirm 

logging.  You will have ambient temperatures until you position the probes inside the refrigerator or freezer. 
Account for this movement when evaluating the data. 
Mount the logger and position the probes. Allow time for  the probes to display readings. Press the 

ALARM

 

button down until CLR appears on the display. The alarms are now reset.

Downloading Data on DicksonWare

Real Time Monitoring: 

Monitor and graph your process as it happens and print and save from real time 

screen. (This feature should be used sparingly as it causes the battery to drain very quickly unless using 
optional AC adapter)

Customize Graphed Data: 

DicksonWare™ calculates Min, Max and Average of all data collected. 

Customize data by eliminating unnecessary data points and customize Min, Max and Average to show only 
desired information.

Export Data: 

A snapshot of your graph or a real-time graph of points can be easily exported to other 

programs such as Excel™ or PowerPoint™.

Super Size Storage: 

With the use of the optional Flash Memory Card and reader you can store 100 

Full Data Loggers. This eliminates the need to physically remove your loggers from their application for 
uninterrupted monitoring.

** CLICK ON THE FEATURES BUTTON IN THE **  
SOFTWARE FOR DETAILED INSTRUCTIONS ON HOW TO USE ABOVE FEATURES
Download: 

Clicking this button will automatically extract all logged data into a Graph and Table format for 

viewing. You may also choose to retrieve data via the optional Flash Memory Card. After Saving data to the 
card, simply insert the card into your reader, open the LOG Folder, then double click on the appropriate LOD 
file which will automatically open DicksonWare™, if not, manually open DicksonWare™. From the top Menu 
bar, click on File > Open and browse to the appropriate drive for your reader and select the LOD file.

DicksonWare™ Software Specifications

Microsoft Windows® compatible 
Allows for simple viewing and zooming of logged data 
Easy set-up of Dickson Data Loggers including:  
 

• 

User selectable sample intervals from 10 seconds to 24 hours  

 

• 

Display temperature in °C or °F  

 

• 

Delayed logger start times  

 

• 

Logger data capacity can be set to wrap data or stop when full  

 

• 

Allow for real time monitoring and graphing.  

 

• 

Effortless exporting of data and graphs to other software  

 

• 

Data can be viewed in tabular (numeric/table) or graphical formats  

 

• 

Fast downloading of logged data - 30 seconds (typical) from full logger  

 

• 

Even shows battery power status for battery operated loggers 

12.



Содержание VFC320

Страница 1: ...Software Specifications Warranty Factory Service Returns Calibrations Product Specifications Accessories Operating Instructions Getting Started Getting Started DicksonWare Software DicksonWare Softwa...

Страница 2: ...H Sensor Type N A N A RH Accuracy N A N A Storage Capacity 32 000 div x 2 32 000 div x 2 Resolution 0 1 0 1 Response Time 63 1 minute 1 minute Accessories for current pricing go to www dicksondata com...

Страница 3: ...installed in the logger will reduce battery life by 50 If you notice Err on the display please refer to the Troubleshooting section of this manual Hardware Display These loggers have a continuous disp...

Страница 4: ...lect USB or Serial depending on the type of download cable Click CONTINUE A setup window pops up with five tabs The Identification tab is chosen All fields should be automatically filled in The Model...

Страница 5: ...creen This feature should be used sparingly as it causes the battery to drain very quickly unless using optional AC adapter Customize Graphed Data DicksonWare calculates Min Max and Average of all dat...

Страница 6: ...is full In Wrap mode the Logger will begin to overwrite the oldest data in its memory 1 2 3 4 5 6 Specifications Compatible With Microsoft Windows 95 98 2000 NT XP PC Requirements PC with 386 MHz or...

Страница 7: ...ge of the power of a PC and software Store the data as you would store any document on your PC Retrieve archived data as easily as opening a file on your PC Share the data as you would any PC file ema...

Страница 8: ...to misuse or neglect Factory Service Returns Contact the factory 630 543 3747 for a Return Authorization RA Number before returning any instrument The model number serial number and a purchase order...

Страница 9: ...mperature Points Documentation of one customer specified point Should be selected in addition to one of the above calibration options Why should I recalibrate my instrumentation Over time dirt dust an...

Страница 10: ...ct Specifications Accessories Operating Instructions Getting Started Getting Started DicksonWare Software DicksonWare Software FAQ FAQ Troubleshooting Warranty Factory Service Returns Calibrations DIC...

Отзывы: