OPERATOR’S MANUAL
14 / CONTROLS
ISO
6
Version 4 Quick Start Guide
6011662 Rev B
Figure 9
Valve Calibration
LIMIT OUTPUT (GRANULAR)
In certain instances, it is necessary to limit the output of the
control channel before running a valve calibration. System
capacities are greater than the actual desired capacities. These
features allow setting the maximum output of the channel to
prevent machine damage.
TO PERFORM A LIMIT OUTPUT:
1. At the Valve Calibration screen, press the
LIMIT OUTPUT
button to access the Limit Output screen.
2.
Move the implement to the “raised” position.
3. Apply the tractor brakes and lock in the applied position.
4.
Put the transmission in “park” or in a locked, neutral position.
5. Engage hydraulic system.
6. Run engine at normal operating RPM until hydraulic fluid is
at normal operating temperature.
7. To change the valve position, press the Increment or
Decrement buttons repeatedly until the desired minimum or
maximum output value is reached.