DiBO n.v. 68
8. Technical data
8.1. General
In this chapter you find the most important technical data of the range where your machine belongs.
Possibly additional technical documentation off your machine can be included as an annex under the chapter
“Machine documentation”.
8.1.1. Machine statement
See end of book.
8.2. General data
- Maximum reactive force of the sprinklers:
<60N
- Minimum water pressure (at LP entrance):
200 kPa (2 bar)
- Maximum water pressure (at LP entrance):
300 kPa (3 bar)
-
Minimum
water
temperature:
1
°C
- Maximum water temperature:
See technical data
- Sufficient water supply at drinking water quality (Directive 98/83/EG)
- The use of an extra water filter is recommended
8.3. Accessories
1 x user manual
8.4. Vibration measurement (hand/arm) - rotating head
As previously mentioned, when using the lance with rotating head of the cleaner (note: not all cleaners have a
lance with rotating head), the action values will be reached sooner. Below, a table is mentioned with the vibration
intensity and exposure time (in hours) of the lances with rotating head on a weekly basis.
The measurements were carried out in the capacity of an accredited laboratory.
This measurements were carried out according to the Royal Decree of 7 July 2005 and EN-ISO 5349:1.
Type (irrespective of elec-
trical start or manual start)
Vibration intensity
(AeqSum)
Exposure time (action) on
weekly base
Exposure time (limit) on
weekly base
PTL-M 200/15 ED
0.5 m/s²
+ 40 h
+ 40 h
PTL-M 200/18
12.6 m/s²
1.34 h
6.16 h
PTL-M 250/13
8.9 m/s²
3.10 h
12.42 h
PTL-L 350/16
0.3 m/s²
+ 40 h
+ 40 h
Note: the version with reel reduces the vibration exposure time.
Increasing the water temperature (for ex.: through the hotbox) does not raises the vibration exposure time.
9. After care
Содержание 1.780.484
Страница 2: ...DiBO n v 2...
Страница 93: ...DiBO n v 93 11 Technical data...