Страница 1: ...Mod GVV 1 Production code TMV10S 02 2017 ...
Страница 2: ...MANUALE DI MANUTENZIONE SERVICE MANUAL MANUEL D ENTRETIEN WARTUNGSHANDBUCH MANUAL DE MANTENIMIENTO PARETE VINO ...
Страница 3: ...e controller The inner fans are broken Replace inner fans I Mist appears on the doors The ambient humidity is very high Excise cause or switch on the anti fog device optional The inside temperature is too low Turn up the unit display temperature Doors don t close properly The unit display isn t on an even surface Level the unit display on a straight surface adjusting the pins None of the led light...
Страница 4: ...ooling unit D POWER SUPPLY REPLACEMENT OPERATION A TO B ACCOMPLISHED FIRST D1 Extract the defective power supply secured on the tank s inner lining D2 Disconnect the power supply from the wiring D3 Connect the new power supply as above E LEDS REPLACEMENT OPERATION ON POINT A TO BE ACCOMPLISHED FIRST RGB LED LIGHTS E1 Loosen terminal screws to connect the LEDS from the controller E2 Extract the bro...
Страница 5: ... at a time WHITE LEDS E5 Disconnect the broken LED strips from the power supply E6 Extract the broken LED strips from the guide operating with a screwdriver E7 Insert the new LED strips in the aluminium profiles and extract the 4 cables from the holes in the basin E8 Reconnect to the power supply matching the polarity F1 Unscrew the screws holding the receptor to the tank F2 Disconnect the power s...
Страница 6: ...m retrieve the refrigerating gas following the legislation in force Proceed to the compressor condensator replacement carefully replacing the dehydrating filter Once the refrigerating circuit in reconnected test the tightness of the cooling system Empty the circuit using a vacuum pump at this stage reload the cooling system using the same type of refrigerating gas and the same amount recommended o...