background image

 

 

UM-PM-039 

 

DA9070 / DA9231 Fuel Gauge Development Kit 

NDA Confidential 

User Manual 

Revision 2.1 

28-Oct-2018 

 

18 of 18 

© 2018 Dialog Semiconductor 

Revision History 

Revision 

Date 

Description 

1.0 

12-12-2017 

Initial version 

2.0 

28-10-2018 

Updated for EVAL 3 

 
 
 
 
Disclaimer 

Information in this document is believed to be accurate and reliable. However, Dialog Semiconductor does not give any representations or 
warranties, expressed or implied, as to the accuracy or completeness of such information. Dialog Semiconductor furthermore takes no 
responsibility whatsoever for the content in this document if provided by any information source outside of Dialog Semiconductor. 

Dialog Semiconductor reserves the right to change without notice the information published in this document, including without limitation the 
specification and the design of the related semiconductor products, software and applications.  

Applications, software, and semiconductor products described in this document are for illustrative purposes only. Dialog Semiconductor makes 
no representation or warranty that such applications, software and semiconductor products will be suitable for the specified use without further 
testing or modification. Unless otherwise agreed in writing, such testing or modification is the sole responsibility of the customer and Dialog 
Semiconductor excludes all liability in this respect.  

Customer notes that nothing in this document may be construed as a license for customer to use the Dialog Semiconductor products, software 
and applications referred to in this document. Such license must be separately sought by customer with Dialog Semiconductor. 

All use of Dialog Semiconductor products, software and applications referred to in this document are subject to Dialog Semico

nductor’s 

Standard 

Terms and Conditions of Sale,

 available on the company website (

www.dialog-semiconductor.com

) unless otherwise stated.  

Dialog and the Dialog logo are trademarks of Dialog Semiconductor plc or its subsidiaries. All other product or service names are the property of 
their respective owners.  

© 2018 Dialog Semiconductor. All rights reserved.  

 

Contacting Dialog Semiconductor 

United Kingdom (Headquarters) 

Dialog Semiconductor (UK) LTD 

Phone: +44 1793 757700 

Germany 

Dialog Semiconductor GmbH 

Phone: +49 7021 805-0 

The Netherlands 

Dialog Semiconductor B.V. 

Phone: +31 73 640 8822 

North America 

Dialog Semiconductor Inc. 

Phone: +1 408 845 8500 

Japan 

Dialog Semiconductor K. K. 

Phone: +81 3 5425 4567 

Taiwan 

Dialog Semiconductor Taiwan 

Phone: +886 281 786 222 

Singapore 

Dialog Semiconductor Singapore 

Phone: +65 64 8499 29 

Hong Kong 

Dialog Semiconductor Hong Kong 

Phone: +852 3769 5200 

Korea 

Dialog Semiconductor Korea 

Phone: +82 2 3469 8200 

China (Shenzhen) 

Dialog Semiconductor China 

Phone: +86 755 2981 3669 

China (Shanghai) 

Dialog Semiconductor China 

Phone: +86 21 5424 9058 

 

Email:  

[email protected] 

Web site:  

www.dialog-semiconductor.com 

 

 

Содержание DA9070

Страница 1: ...NDA Confidential User Manual DA9070 DA9231 Fuel Gauge Development Kit UM PM 039 Abstract This document describes the hardware in the DA9070 DA9231 Fuel Gauge Evaluation and Development Kit...

Страница 2: ...ault Settings 4 Board overview 5 Key Features 5 System Diagram 6 Chip Evaluation Mode 7 Evaluation Mode Basic Set up 7 DA9070 Evaluation 9 Recommended Operating Conditions 10 Connectors for DA9070 Eva...

Страница 3: ...able 1 Recommended Operation Conditions 10 Table 2 DA9070 Input and Output Connectors 10 Table 3 Default Load Resistor Values 13 Table 4 Recommended Operation Conditions 14 Table 5 DA9231 Input and Ou...

Страница 4: ...loads battery profile data and runs the fuel gauge performance test This GUI is used to develop a software fuel gauge based on the user s battery Default Settings The DA9070 settings are loaded from...

Страница 5: ...Profile Circuitry Battery Connector Ref Fuel Gauge IC U5 Figure 1 DA9070 Fuel Gauge EVK Board Top View Key Features Single USB connector supports both charging power and communication with PC Support...

Страница 6: ...etween USB and UART SPI ports JTAG Communication port for STM32L151 MCU firmware update LTC2941 Reference Coulomb count based fuel gauge IC Battery V I Monitor Circuitry to monitor battery voltage cur...

Страница 7: ...e evaluated for current consumption efficiency load line regulation load line transient etc without battery DA9070 can also be evaluated for sequence system load transient while the battery being plug...

Страница 8: ...ery to J27 The positive terminal is labeled VBAT_P adjacent to the red test point TP26 Plug in a USB cable into J8 connector Connect the USB cable to either a traveler adapter or a PC The Yellow LED l...

Страница 9: ...amage to the EVK board For test and measurement set up please refer to Table 2 for descriptions of connectors on the EVK board DA9070 VBAT_SNS GND TEMP_SNS ILIM_PWR ILIM_CHG ITER_CHG NTC VBAT AGND VDD...

Страница 10: ...ectors Pin Names Descriptions J1 VDD_BUCK_M S S and are terminals for connecting an external load to the DA9070 VDD_SYS S and S are kelvin sense points for DA9070 Buck input For input voltage measurem...

Страница 11: ...to pin 3 The load switch is controlled by the MCU during battery profiling For evaluation use jumper positions 1 and 2 J14 S and J14 S pins are kelvin sense points of DA9070 input VDD_PWR J16 VDD_SYS_...

Страница 12: ...ommand through the GUI The DA9070 fuel gauge outputs IMON and VBAT_DIV are directly controlled by the MCU These registers should not be controlled by the user Charging and Discharging Battery charging...

Страница 13: ...1 4W R11 Load resistor for LDO2 rail 154 1 8W R8 Load resistor for Boost rail 3 3k 1 8W If an external load needs to be applied to any rail first remove the jumper previously installed on LDO0 1 2_LD...

Страница 14: ...the EVK board For test and measurement set up please refer to Table 5 for descriptions of connectors on the EVK board DA9231 SW VBUCK_SNS PGND VDD_SYS VDD VDD_LDO VLDO SDA SCL GPO GND IC_EN HOST Buck...

Страница 15: ...V_USB or VDD_SYS_M of DA9070 S and S are kelvin sense points for DA9231 Buck input J22 VDD IC_EN AGND Set IC_EN to VDD to automatically start the DA9231 when VDD is applied Set IC_EN to AGND to comple...

Страница 16: ...This profile is then used by the pre loaded Dialog algorithm for the SOC fuel gauge If the included 80mAh battery is used battery profiling is not necessary the MCU is pre loaded with both the fuel ga...

Страница 17: ...le process includes battery profiling lookup table generation and fuel gauge performance test Board calibration can also be performed using the PPM software The main PPM windows are shown in Figure 10...

Страница 18: ...es all liability in this respect Customer notes that nothing in this document may be construed as a license for customer to use the Dialog Semiconductor products software and applications referred to...

Отзывы: