 1:  Introduction 

This Linear LED light is designed for illumination of industrial locations. It uses the latest in solid state 
lighting technology for long life, low maintenance, and high efficiency. 
 
The unique optical design focuses light downward to where it is needed, giving improved efficiency over 
a conventional HID luminaire. 
 
An internal, universal input, power-factor-corrected switch-mode supply allows it to be used from any 
nominal 100V-277V, 50/60Hz AC supply without any variation in light output. 
 

Models listed above are SUITABLE FOR WET LOCATIONS in unclassified locations: 

       
 

Temperature Code:  T5 for 2' model, T5 for 4' model 

Ambient Temperature Range:  -40C to +65C 

 

Note:  Save these instructions for future reference. 

Содержание DUROSITE LPM3C4D2P

Страница 1: ...ed for illumination of industrial locations It uses the latest in solid state lighting technology for long life low maintenance and high efficiency The unique optical design focuses light downward to where it is needed giving improved efficiency over a conventional HID luminaire An internal universal input power factor corrected switch mode supply allows it to be used from any nominal 100V 277V 50...

Страница 2: ... an equipment grounding conductor Warning DO NOT let power cord touch hot surfaces DO NOT mount near gas or electric heaters Equipment should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel The use of accessory equipment not recommend by the manufacture may cause an unsafe condition DO NOT use this equipment for other than it s intended ...

Страница 3: ...r cord grips where shown in figure 2 Use conductive pipe sealant for all metal fittings and conduit Use Teflon tape for polycarbonate 3 4 NPT pipe plugs o Warning If there is moisture present or chance of it in the conduit system then necessary precautions should be taken by the installer to prevent the moisture from entering thru the cable or conduit and entering the fixture Failure to comply wit...

Страница 4: ...is It is recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B Recommended Practice for Electrical Equipment 2 If the lens Figure 4 below requires periodical cleaning to ensure continued photometric performance Clean the lens with a damp non abrasive lint free cloth If not sufficient use mild soap and water 3 Inspect the outside of the Luminaire housing to ens...

Страница 5: ...49 F 65 C Power factor 0 9 ATHD 20 Dimensions L x W x H See Figure 5 Weight 8 lbs 3 62 kg 2 11 lbs 4 98 kg 4 Intertek Certified to UL 844 and C22 2 No 137 Figure 5 All statements technical information and recommendations contained herein are based on information and tests we believe to be reliable The accuracy or completeness thereof is not guaranteed In accordance with Dialight Corporation Terms ...

Страница 6: ...cument No 9100 127 2209 99 Rev A Page 6 of 6 1501 Route 34 South Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 www dialight com REV ECO No DRN CHK APP QA CM DATE A 17702 WSL JCA SB LP JN 4 29 14 ...

Отзывы: